In order to access the screw which gradua-
tes the gas flow through the taps in hob
CGC 4G AI AL, remove the screws that fix
the cover protecting the taps to the case
and lift the cover.
Others hobs
•
Remove the tap controls by pulling them
u p w a rds stro n g l y.
•
Light the burners at their minimum setting.
•
Use a small screw driver to remove the
s c rew on the right or centre of the plug of
the gas key (turn left for a big flame and
right for a small flame).
•
Once the setting has been graduated
check the the flame remains at its mini-
mum setting when the control is bru s q u e l y
t u rned between the maximum and the
minimum setting.
Models CG LUX-75 and CG LUX-86 re g u l a t e d
for town gas can not be transformed to opera-
te neither natural nor butane gas.
The only intervention necessar y for the trans-
f o rmation is the replacement of the gas nozz-
les and their setting.
TEKA INDUSTRIAL, S.A.
will not accept
responsibility for incorrect hob operation if the
gas transformation and regulation of minimum
b u rner settings are not carried out by TEKA’s
official Technical Ser vice.
15