Install properly sized pressure gauges in
suction and discharge lines near the pump
ports so that operation of the pump and
system can be easily observed. Should cavi-
tation, vapor binding, or unstable operation
occur, widely fluctuating discharge pres-
sures will be observed.

Such gauges provide a positive means of determin-
ing actual system conditions and can be used to
great advantage in evaluating system problems.

2-3. Electrical

2-3.1. General

Except where indicated, all Dynapump LE Series are
started with full line voltage.  Refer to Paragraph 3-3,
Page 9, for checking direction of rotation. Also see
Wiring Diagram Figure 2-1, Page 7 for proper wiring
connections.

2-3.2. Thermal Cutouts

All Dynapump LE Series are fitted with a thermal
cutout. The cutout is a heat-sensitive bimetallic
switch mounted in intimate contact with the stator
windings. The TCO wiring diagram is shown in Fig-
ure 2-1, Page 7.  Maximum holding coil currents is
3.1 AMPS for 115 volts.

WARNING

Do not connect TCO in series with main
power lead. Excessive heat build up in the
winding area opens the normally closed
thermal switch, which, in turn, opens the
holding coil circuit, shutting off power to
the pump. Be sure to connect the thermal
cutout as required.

Thermal cutouts in Class H insulated motors are
set to open at 356

o

 F (180

o

 C).  If the motor cuts out

because of TCO action, there will be a time delay
before the motor can be restarted. The motor must
be restarted manually.

DO NOT RESTART UNTIL YOU DETERMINE THE
CAUSE OF THE OVERHEATING.

Page 6

WARNING

The thermal cutout switch does not provide
protection against fast heat build-up result-
ing from locked rotor conditions, single
phasing or heavy overloads. The current
overload relay heaters in the magnetic
starter must provide for this protection. The
rating of the heaters should be high enough
to avoid nuisance cut outs under running
loads, but must not be oversized. Refer to
Table 2-1, Page 7, for starting and running
electrical characteristics. It is recom-
mended that “quick trip” (Class 10) heat-
ers be used because of the more rapid re-
sponse time.

2-3.3. Starting Equipment

Motor starters (normally not supplied with Dynapump
LE Series) should be sized to handle the load re-
quired. Full Load HP, Full Load Amps and Start KVA
Data is listed in Table 2-1, Page 7.

Heaters in the starters should be sized for the am-
perage shown on the Dynapump LE Series name-
plate. DO NOT size heaters in excess of 10% of full
load amp rating. In order to provide complete protec-
tion for Dynapump LE Series motors under all con-
ditions, it is recommended that “

quick trip

” (Class

10) type heaters be used in the starters where avail-
able.  Standard heaters provide adequate protection
for Dynapump LE Series motors under starting or
normal running conditions, but require a greater
length of time than “

quick trip

” type heaters to cut out

if the motor is subject to locked rotor or overload
conditions.

CASE I - 460 Volt, 3-Phase Dynapump LE Series (See
Figure 2-1, Page 7).

Typical 3-phase across-the-line magnetic starter with
start-stop push button station shown.

Thermo switch (thermal cutout inside Dynapump LE
Series motor) is wired as shown in Figure 2-1, Page
7.

Be sure to size heaters properly. Motor data can be
found on the pump nameplate.

Summary of Contents for DynaPump LE Series

Page 1: ...Instruction Manual for Installation Operation Maintenance DYNAPUMP Sealless Leakproof Canned Motor Pump LE SERIES 4 09...

Page 2: ...This page intentionally blank...

Page 3: ...Piping Data 5 2 3 Electrical 6 2 3 1 General 6 2 3 2 Thermal Cut Out 6 2 3 3 Starting Equipment 6 2 3 4 Bearing Wear Monitor 7 SECTION 3 OPERATION 3 1 Procedure Before Initial Start up 9 3 2 Priming...

Page 4: ...pump LE Series Bearing Wear Limit 14 4 2 Dynapump LE Series Playing Gap of Rotor Axial End Play 14 4 3 Dynapump LE Series Adjusting Value of Gap g 14 4 4 Dynapump LE Series Tightening Torque for Impel...

Page 5: ...ed out and signed by a responsible individual at the customer s facility Refer to copy of Decontamination Form in the Appendix of the Instruction Manual It is recommend that as a minimum a set of bear...

Page 6: ...This page intentionally blank...

Page 7: ...ly in conjunction with the leak proof terminal post assembly provides the secondary con SECTION 1 General Information Page 1 Figure 1 1 Dynapump LE Series Standard Circulation tainment This design pre...

Page 8: ...journal area Each bearing is manufactured to close tolerances for a high degree of concentricity and is held in a bearing housing by a retaining screw Bearings are easily replaced by re moving the re...

Page 9: ...precau tions The pump may be under pressure Always loosen the drain plug slowly to relieve any inter nal pressure before attempting to disassemble the pump Adequate precautions must be taken if the li...

Page 10: ...This page intentionally blank...

Page 11: ...that sufficient NPSH Net Posi tive Suction Head is provided over vapor pressure of the fluid at the pump inlet NPSH requirements at the design point are stated on the pump order data sheet For additio...

Page 12: ...be the same size as the pump discharge port diameter If discharge piping is of considerable length use larger diameter pipe one or two sizes larger If the pump is to discharge into a closed system or...

Page 13: ...age 6 WARNING The thermal cutout switch does not provide protection against fast heat build up result ing from locked rotor conditions single phasing or heavy overloads The current overload relay heat...

Page 14: ...rotor assembly When the rotor is perfectly centered in the stator between the coils the electric currents are balanced and no voltage is de tected When bearing wear occurs the rotor moves toward one...

Page 15: ...ve until rated discharge pressure is obtained h Remove obstructions in the impeller i Reverse any two motor leads and check with phase sequence meter See Paragraph 3 3 j Impeller must be repaired or r...

Page 16: ...This page intentionally blank...

Page 17: ...e pump Pump should operate with very low noise and vibrations Excessive or abnor SECTION 3 Operation 3 1 Procedure Before Initial Start Before starting the pump for the first time make sure suction an...

Page 18: ...ed periodically during operation If the initial reading TRGi was not re corded then the color coding system shown in sec tion 2 3 4 Page 7 may be used to determine bearing changing intervals If the TR...

Page 19: ...chips Refer to Table 4 1 L Page 14 for excess wear on thrust surface Check this dimension after bearing has been removed B Wear inside of bearing bore Refer to Table 4 1 A B on Page 14 4 2 2 Shaft Sl...

Page 20: ...anti rotational key or pin Install the Flat Washer Lock Washer and Lock Bolt insuring that the Lock Washer tab is engaged in the slot in the Shaft Sleeve Torque Lock Bolt per Table 4 4 Page 14 This b...

Page 21: ...Figure 4 2 g Gap Figure 4 1 Bearing Wear Page 13...

Page 22: ...98 in Motor Frame Number A B L 3111 3115 15B 0 3mm 0 012 in 44 2mm 1 746 in 3115 15A 3211 3215 15B 0 4mm 0 016 in 49 2mm 1 937 in 3215 15A 3311 3315 15B 0 4mm 0 016 in 59 2mm 2 331 in 3315 15A 0 4mm 0...

Page 23: ...APPENDIX...

Page 24: ...____________________________________________________________ 2 ACTUAL OPERATING CONDITIONS TRANSFER CIRCULATION FLOW _____________________________________GPM SUCTION PRESSURE _____________________PSIG...

Page 25: ...__________________ DECONTAMINATION INFORMATION All pumps parts must be completely decontaminated and all information in this section must be completed prior to shipment to our factory or service cente...

Page 26: ...ONBOXFROMTHELEAD NIPPLEANDCHIPAWAYTHEPOTTINGCOMPOUNDFROMTHELEADNIPPLE B2 POSITIONTHESTATORASSEMBLYWITHTHELEADNIPPLEDOWNANDINTRODUCEAN APPROPRIATENEUTRALIZINGFLUIDTOTHERELIEFVALVEADAPTER THEFLUIDWILLEX...

Page 27: ...A 4...

Page 28: ...A 5...

Page 29: ...A 6...

Page 30: ...A 7...

Page 31: ...9919 Website www teikoku usa com E mail info teikoku usa com Chempump 959 Mearns Road Warminster PA 18974 Phone 215 343 6000 Fax 267 486 1037 Website www chempump com E mail chempump chempump com Midw...

Reviews: