background image

16-

i.)  For  DMX  reset,  put DMX  value  of CH-8 & CH-16 to 255, the unit will reset after  about 

five seconds.

      For lamp on, put DMX value of CH-8 to 247 & CH-16 to 255.

      For lamp off, put DMX value of CH-8 to 239 & CH-16 to 255.

ii.) For color sound activated, put DMX value of CH-6 to 248-255.

   

For gobo sound activated, put DMX value of CH-9 to 248-255.

17-

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 

channels.

1.

If  you  use  a  controller  with  5  pins  DMX  connector, you  need  to  use  a  5  to  3  pin 

adapter.

2.

At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 

1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it 

in the DMX-output of the last unit.

3.

Connect the unit together in a “daisy chain” by XLR plug cable from the output of the 

unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable. 

DMX512 is  a very high-speed signal.  Inadequate  or damaged cables, soldered joints 

or corroded connectors can easily distort the signal and shut down the system.

4.

The  DMX  output and  input  connectors are pass-through  to  maintain  the DMX circuit, 

when power is disconnected to the unit.

5.

Each  lighting  unit  needs  to  have  an  address  set  to  receive  the  data  sent  by  the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).

6.

The end of the DMX512 system should be terminated to reduce signal errors.

7.

3 pin XLR connectors are more popular than 5 pins XLR.

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 

5.5. DMX512 Connection 

Summary of Contents for 85-05275

Page 1: ...ion Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 DMX Controller 5 4 DMX 512 Configuration 5 5 DMX 512 Connection 6 Troubleshooting 7 Ma...

Page 2: ...ized technical assistance center Always use the same type spare parts Don t connect the device to any dimmer pack Do not touch any wire during operation as there might be a hazard of electric shock 3...

Page 3: ...hannel 15 Tilt 16 bit Channel 5 Shutter Shaking Channel 16 Reset Lamp on off Channel 6 Color Channel 17 Red LED Channel 7 No Function Channel 18 Green LED Channel 8 No Function Channel 19 Blue LED Cha...

Page 4: ...not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot In case of replacement of the lamp or maintenance do not open the...

Page 5: ...ode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angle left to right to left 160 Tilt movement angle 90 60 above ho...

Page 6: ...normal mode for the fixture putting on the floor 11 Display inversion mode for the fixture fixing under ceiling Press the button up to when the is blinking on the display Pressing button the unit will...

Page 7: ...offset mode use and button up to when the is shown on the display Pressing button and the display will blink Use and button to adjust the gobo home position Once the gobo has been selected press the...

Page 8: ...control all the other units for Stand by Function and Mode Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 T wo light strobe X Y moving show pattern selection Show 1 Sh...

Page 9: ...lug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input of the next unit The cable cannot be branched or split...

Page 10: ...PCB might be out of condition 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the 19...

Page 11: ...screws E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 21...

Page 12: ...ulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics a...

Reviews: