background image

2-

Please keep this User Guide for future consultation. If you sell the unit to another user, 

be sure that they also receive this instruction booklet.

Unpack and check carefully there is no transportation damage before using the unit.

Before  operating,  ensure  that  the  voltage and  frequency  of  power  supply  match  the 

power requirements of the unit.

It’s important  to  ground  the  yellow/green conductor  to earth in  order  to avoid electric 

shock.

The unit is for indoor use only. Use only in a dry location.

The  unit must  be  installed in a  location  with adequate ventilation, at  least 50cm  from 

adjacent surfaces. Be sure that no ventilation slots are blocked.

Disconnect main power before fuse/lamp replacement or servicing.

Replace fuse/lamp only with the same type.

Make sure there are no  flammable  materials close  to  the unit while operating,  as it is 

fire hazard.

Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but 

always by taking its base.

Maximum  ambient temperature  is Ta  : 40 .  Don’t  operate it  where  the  temperature is 

higher than this.

Unit  surface  temperature  may  reach  up  to  85 .  Don’t  touch  the  housing  bare-hand 

during its operation, and allow about 15 minutes to cool down before replacing bulb or 

serving, as the unit could be very hot.

In the event of serious operating problem, stop using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage 

or  malfunction.  Please  contact  the  nearest  authorized  technical  assistance  center. 

Always use the same type spare parts.

Don’t connect the device to any dimmer pack.

Do not touch any wire during operation, as there might be a hazard of electric shock.

3-

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture.

Never touch bulb with bare fingers, as it is very hot after using.

Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.

Do not start on the unit without bulb enclosure or when housing is damaged.

The  housing,  the  lenses,  or  the ultraviolet  filter  must  be  replaced  if  they  are  visibly 

damaged.

Do not look directly at the light while the bulb is on.

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 

repairs by yourself. In the unlikely event your unit may require service, please contact your 

nearest dealer.

The unit should be mounted via its screw holes on the bracket (please refer to the drawing 

below).  Always  ensure  that  the  unit  is  firmly  fixed  to  avoid  vibration  and  slipping  while 

operating.  Always  ensure  that  the  structure  to which  you  are  attaching  the  unit is secure 

and  is able to support  a weight of  10  times  of the unit’s weight. Also  always  use a safety 

cable that can hold 12 times of the weight of the unit when installing the fixture. 

The equipment must be fixed by professionals. And it must be fixed at a place where is out of 

the touch of people and has no one pass by or under it.

  1. Safety Instruction

WARNING 

Please read care fully the instruction, which includes important 

information about the installation, usage and maintenance.

Warning

Caution

Installation

?

?

Summary of Contents for 85-05275

Page 1: ...ion Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 DMX Controller 5 4 DMX 512 Configuration 5 5 DMX 512 Connection 6 Troubleshooting 7 Ma...

Page 2: ...ized technical assistance center Always use the same type spare parts Don t connect the device to any dimmer pack Do not touch any wire during operation as there might be a hazard of electric shock 3...

Page 3: ...hannel 15 Tilt 16 bit Channel 5 Shutter Shaking Channel 16 Reset Lamp on off Channel 6 Color Channel 17 Red LED Channel 7 No Function Channel 18 Green LED Channel 8 No Function Channel 19 Blue LED Cha...

Page 4: ...not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot In case of replacement of the lamp or maintenance do not open the...

Page 5: ...ode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angle left to right to left 160 Tilt movement angle 90 60 above ho...

Page 6: ...normal mode for the fixture putting on the floor 11 Display inversion mode for the fixture fixing under ceiling Press the button up to when the is blinking on the display Pressing button the unit will...

Page 7: ...offset mode use and button up to when the is shown on the display Pressing button and the display will blink Use and button to adjust the gobo home position Once the gobo has been selected press the...

Page 8: ...control all the other units for Stand by Function and Mode Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 T wo light strobe X Y moving show pattern selection Show 1 Sh...

Page 9: ...lug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input of the next unit The cable cannot be branched or split...

Page 10: ...PCB might be out of condition 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the 19...

Page 11: ...screws E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 21...

Page 12: ...ulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics a...