background image

18-

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

1.

Check the connect power and main fuse.

2.

Measure the mains voltage on the main connector.

3.

Check the power on LED.

1.

DMX LED should be on. If not, check DMX connectors, cables to see if link properly.

2.

If the DMX LED is on and no response to the channel, check the address settings and 

DMX polarity.

3.

If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one.

4.

Try to use another DMX controller.   

5.

Check to  see  if  the  DMX  cables  run  near or  run alongside to high  voltage cables  that 

may cause damage or interference to DMX interface circuit. 

1. You  may  have  a  break  in  the  DMX  cabling.  Check  the  LED  for  the  response  of  the 

master/ slave mode signal.

2. Wrong DMX address in the unit. Set the proper address.

1.

Make sure the unit is not receiving DMX signal.

2.

Check microphone to see if it is good by tapping the microphone.

1. T he stepper motor might be damaged or the cable connected to the PCB is broken.

2. T he motor’s drive IC on the PCB might be out of condition.

1. T he lamp is not working well. Check the main voltage either too high or too low.

2. Internal temperature may be too high. Check and if necessary replace the fan on the 

19-

head.

1. Turn off the main power.

2. Unscrew all the screws (A) and open the base-housing cover (B).

3. Unscrew all the screws (C) and open the arm cover (D).

4. Unplug all the connect wires that from the arm to the bottom.

5. Unscrew the screws (E) and remove the fixture head.

6. Loose the screws (F), then loose the screws (G).

7. Change a new belt (H) , put the belt around the axis gear and motor gear.

8. Screwed the screws (G), install the new belt and adjust the belt tension properly. Note: do 

not fix belt too tight as it is easy to rupture.

9. Plug all the connect wires back that form the bottom to the arm.

10. Reverse the procedures from point 5 to point 2.

  6. Troubleshooting 

Following  are a  few  common  problems  that  may  occur  during  operation.  Here are 

some suggestions for easy trouble shooting:

A. The  unit does not work, no light and the  fan does not work

B. Not responding to DMX controlle r

C. Some  units don’t respond to the easy controlle r 

D. No response  to the sound

E. One  of the channe ls is not working well

F. The lamp is cutting out intermitte ntly

G. If The  pan be lt is broken

Summary of Contents for 85-05275

Page 1: ...ion Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 DMX Controller 5 4 DMX 512 Configuration 5 5 DMX 512 Connection 6 Troubleshooting 7 Ma...

Page 2: ...ized technical assistance center Always use the same type spare parts Don t connect the device to any dimmer pack Do not touch any wire during operation as there might be a hazard of electric shock 3...

Page 3: ...hannel 15 Tilt 16 bit Channel 5 Shutter Shaking Channel 16 Reset Lamp on off Channel 6 Color Channel 17 Red LED Channel 7 No Function Channel 18 Green LED Channel 8 No Function Channel 19 Blue LED Cha...

Page 4: ...not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot In case of replacement of the lamp or maintenance do not open the...

Page 5: ...ode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angle left to right to left 160 Tilt movement angle 90 60 above ho...

Page 6: ...normal mode for the fixture putting on the floor 11 Display inversion mode for the fixture fixing under ceiling Press the button up to when the is blinking on the display Pressing button the unit will...

Page 7: ...offset mode use and button up to when the is shown on the display Pressing button and the display will blink Use and button to adjust the gobo home position Once the gobo has been selected press the...

Page 8: ...control all the other units for Stand by Function and Mode Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 T wo light strobe X Y moving show pattern selection Show 1 Sh...

Page 9: ...lug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input of the next unit The cable cannot be branched or split...

Page 10: ...PCB might be out of condition 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the 19...

Page 11: ...screws E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 21...

Page 12: ...ulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics a...