Chapter 4 Software index
4-32
C41
Local
/Remote control select
description
•
Local
mode
Run command
The
Run/Stop pad on the keypad control
s inverter
F04 setting
has no effect on control
.
Frequency command
When C41=000:
the
UP/DOWN pad on the keypad
controls the drive
and the F05 setting
has
no effect
.
When C41=001:
the potentiometer
on the keypad
controls frequency,
and F05 setting
has no
effect
.
• Remote mode
Run command
is by
the run parameter (F04) set
ting
Frequency command from the frequency parameter (F05) set
ting
• Control select mode is
changed by simultaneously pressing
V/RESET and DATA/ENT
keys
(
Drive must be in stop mode
)
Refer to F11~F14
1.)
If the C44 scan time is set to 80 ms
as an example
(i.e N=10) then digital input signals on for less
than
80 msec will be ignored.
2.)
If
the
scan signal
is seen
for N times (scan times), the inverter takes it as
signal
change
. If it is
seen
for
less than N times, it
is seed
as noise. One scan time: 8ms.
3.) User can set scan interval time according to noise in the operation environment. Extend C44/C45
if
noise is
a problem
, however this will reduce the scan response time.
C42/43 (option card) S5/S6 terminal on MFIT Setting
000: Forward
001: Reverse
002: Preset speed command 1
003: Preset speed command 2
004: Preset speed command 3
005: Jog Frequency Command
006: Emergency Stop (E.S.)
007: Base Block (b.b.)
008: Switching to 2
nd
acceleration/ deceleration time.
009: Reset
010: Up Command
011: Down Command
012: Control signal switch
013: Communication control signal switch
014: Acceleration/ deceleration disable
015: Master/ auxiliary speed switch
016: PID function disable
C44: Multi-function input terminal S1~S6 signal scan time (N. msec ×8), N = (1~100 times).
C45: AIN signal scan time (N. msec ×8), N = (1~100 times).