Chapter 4 Software index
4-23
• Torque/Speed curve pattern:
• Operating frequency range: 0~Motor rate frequency
• When the motor output torque is not enough and increase F48 setting value.
• When the motor is
erratic or vibrates
decrease F48 setting value.
• The max. Output torque limit to the inverter
is
current rated.
• If increase F48 setting value then the output current is too large. Please increase C49 setting value
on the same time.
F49 Slip compensation gain (vector), C14=000
Performance: If the motor load
appears
too large, increase slip compensation.
(load current) (compensation gain)
• Torque/Speed curve pattern:
• Operating frequency range: 0~motor rated frequency.
• When the motor output
rotation
speed is too low increase F49 setting value.
• When the motor is
erratic or vibrates,
decrease F48 setting value.
• The max. output
rotation
speed limit to the motor max. setting frequency.
• If increase F49 setting value then the output current is too large. Increase C48 setting value
at
the
same time.
RPM
ΔTe:
Increase output torque capacity
Torque
C %
B %
A %
Q
∆
F
slip
≒
I
¯
Gain
A %
B %
C %
Q
RPM
∆
F
slip
Figure 4-11 Output Torque Capacity
Figure 4-12 Slip Compensation