![TECO F510 series Quick Setting Manual Download Page 25](http://html1.mh-extra.com/html/teco/f510-series/f510-series_quick-setting-manual_1072458025.webp)
24
Group 07: Start /Stop Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Time of PM
Speed
Search
07-45
STP2
Function
Selection
0:STP2 Enable
0
Note6
1:STP2 Disable
Group 08 Protection Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
08-00
Stall
Prevention
Function
xxx0b: Stall
prevention is
enabled in
acceleration
0000b
xxx1b: Stall
prevention is
disabled in
acceleration
xx0xb: Stall
prevention is
enabled in
deceleration
xx1xb: Stall
prevention is
disabled in
deceleration
x0xxb: Stall
prevention
is enabled
in operation
x1xxb: Stall
prevention
is disabled
in operation
0xxxb: Stall
prevention
in operation
decelerates
based on
deceleration
time 1
1xxxb: Stall
prevention
in operation
decelerates
based on
deceleration
time 2
08-01
Stall
Prevention
Level in
Acceleration
20~200 120
08-02
Stall
Prevention
Level in
Deceleratio
n
200V: 330~410 385
400V: 660~820 770
Group 08 Protection Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
08-03
Stall
Prevention
Level in
Operation
30~200 120
08-04
Reserved
08-05
Selection for
Motor
Overload
Protection
(OL1)
xxx0b: Motor
Overload
Protection is
disabled
0001b
xxx1b: Motor
Overload
Protection is
enabled
xx0xb: Cold
Start of Motor
Overload
xx1xb: Hot
Start of Motor
Overload
x0xxb:
Standard Motor
x1xxb: Special
motor
0xxxb:
Reserved
1xxxb:
Reserved
08-06
Start-up
Mode of
Overload
Protection
Operation
(OL1)
0: Stop Output
after Overload
Protection
0
1: Continuous
Operation after
Overload
Protection.
08-07
Motor
Overload
(OL1)
Protection
Level
0: Motor
overload (OL1)
Protection 0
0
Note3
1: Motor
overload (OL1)
Protection 1
2: Motor
overload (OL1)
Protection 2
08-08
Automatic
Voltage
Regulation
(AVR)
0: Enable
0
1: Disable
08-09
Selection of
Input Phase
Loss
Protection
0: Disable
0
1: Enable
08-10
Selection of
Output
Phase Loss
Protection
0: Disable
0
1: Enable
08-11
08-12
Reserved
08-13
Selection of
Over-
Torque
0: Over-Torque
Detection is
Disabled.
0