57
Table 4.4, for fault information during tuning,
cause and corrective action.
Table 4.4 Auto-tuning fault and corrective
actions for PM motor
Error
Corrective action
01
Magnetic pole
alignment tuning
failure (static).
Check the motor tuning
data (22-02).
Check inverter capacity
02
PG option
missing.
Install PG feedback
card.
03
Magnetic pole
alignment auto-
tuning abort
during rotational
auto-tune
Check for active
protection functions
preventing auto-tuning.
04
Timeout during
magnetic pole
alignment during
rotational auto-
tune.
Check motor.
Check motor wiring.
Check brake released.
05
Circuit tuning
time out.
Check for active
protection functions
preventing auto-tuning.
06
Encoder error
Check motor rated
current.
Check PG card
grounding.
07
Warning
Check the motor tuning
data (22-02).
Check motor
connection.
08
Motor current out
of range during
magnetic pole
alignment
(rotational auto-
tune).
Check PG card wiring
Check motor
connection.
09
Current out of
range during
circuit tuning.
Check the motor tuning
data (22-02).
Check inverter capacity
10
Magnetic pole
alignment and
circuit tuning
failed.
Retry magnetic pole
alignment and circuit
tuning.