A -
PRE
SS
URE
C O
NTR
O
L - H
YDRAULIC
C O
NTR
O
L V A
L V E – AD
J U
S T M
ENT
PR
O
C E DURE
(FI
G
. 6.2, 6.3
, 6.4
)
P r o c e dur
e ( fi g . 6 . 2 , 6 . 3 , 6 . 4 )
After having:
1.
Plugged the flexible hose;
2.
Plugged the connection on the hydraulic motor;
3.
Introduced the pressure gauge into the pressure point;
4.
Position the l wrenches for adjustment on the adjustment screw;
5.
Position the hex wrench on the hex lock nut
6.
Holding the hex wrench still, loosen the lock nut a little bit to free the regulation screw;
7.
Slowly turn the adjustment screw clockwise to increase the maximum pressure value or counter-clockwise
to decrease the maximum pressure value until the value of 180 bar (2,610 osi) is reached.
8.
Without moving the hex wrench, close the lock nut.
9.
Activate the flow of oil and check if maximum pressure is correct.
Division: Tecnoter srl
Hyd. Magnet
LQMI
Ver. T
Page 31/38
Rev: 1.0a_En –