INSTRUCTIONS FOR USE
OF REGULATIONS
NOVATEC ISOBUS AND NOVATOP
Tecnoma technologie – 54, rue Marcel Paul – BP 195 – 51206 Epernay
Tel +33(0)3 26 51 99 99 – Fax +33(0)3 26 51 83 51
e – mail
-
www.tecnoma.com
SAS with a capital of 1 174 400 € – RCS Epernay B 350 484 309 – APE 293D
990025
Mars 2012
Page
30/31
Put the sprayer in manual mode using the key
Start the sprayer using the key
of the multi-functions handle or in the complementary mask 2.
Raise the spraying pressure to exactly 3 bars using the keys
and
of the multi-functions
handle or in the complementary mask 2.
Verify the flow of various nozzles using a test tube for exactly one minute.
Stop then the spraying using the key
of the multi-functions handle or in the complementary mask 2.
Divide the quantity obtained by the number of nozzles verified and input the thus obtained value in the
slot l/min
Start the sprayer using the key
of the multi-functions handle or in the complementary mask 2.
Faire monter la pression de pulvérisation à une pression choisie, tout en restant dans la plage
d’utilisation de la buse, à l’aide des touches
et
sur la poignée multifonctions ou dans le
masque complémentaire 2.
Verify the flow of various nozzles using a test tube for exactly one minute.
Stop then the spraying using the key
and put the sprayer back to automatic mode with the
key
.
Divide the quantity obtained by the number of nozzles verified and input the thus obtained value in the
slot l/min
Input also the pressure of the second measure in the calibration mask.
The calibration procedure is now completed. The accuracy of the result depends on the care brought
during the measurement and the precision of the measuring tools.