The key
allows switching between the presentations of both figures shown above. The
presentation of the figure nozzles mask/pressure calculation allows defining a range of use. You can
define the desired spraying speed as well as the minimal and the maximal work pressure. The max. and
min. volumes are then based on these data.
The nozzles mask/pressure calibration figure shows the calibration mask of standardized nozzles. It is
possible to set a volume to spread at a given pressure (3 bar) and choose the nozzle in accordance with
these constants.
6.18.2
6.18.2
6.18.2
6.18.2
Calibration p
Calibration p
Calibration p
Calibration proc
roc
roc
roce
e
e
edure
dure
dure
dure of a nozzle
of a nozzle
of a nozzle
of a nozzle::::
Fill the tank with clear water
Put the sprayer in manual mode using the key
Start the sprayer using the key
of the multi-functions handle or in the complementary mask 2.
Raise the spraying pressure to 3 bars using the keys
and
of the multi-functions handle or in
the complementary mask 2.
Verify the flow of various nozzles using a test tube for exactly one minute.
Stop then the spraying using the key
and put the sprayer back to automatic mode with the
key
.
Divide the quantity obtained by the number of nozzles verified and input
the obtained value in the slot l/min.
The calibration procedure is thus completed. The calibration mask now
looks like in the opposite figure.
Standardized nozzle calibrated at 3 bar
The key appears in the calibrated nozzle mode. The nozzle calibration currently selected can be
cancelled by pressing on this key.
The c
The c
The c
The calibra
alibra
alibra
alibration of non standardized nozzles
tion of non standardized nozzles
tion of non standardized nozzles
tion of non standardized nozzles is different. We input here
two reference points which define the nozzle flow. The first reference
point is fixed at 3 bar, just like for the standardized nozzles. The second
reference point is free. This second reference point can also be set to
above 3 bars, depending on the usage range of the nozzle. Opposite Fig.
The calibration of non standardized nozzles
The calibration of non standardized nozzles
The calibration of non standardized nozzles
The calibration of non standardized nozzles
The calibration can be achieved by following the following instructions, step by step:
Fill the tank with clear water.