Tecnoautomation TASFD6T Manual Download Page 11

 

 

 

 

 
 

Add users 

 

Add PIN code by assigning a specific user ID

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

  

(Digit Master Code) 

 

Add a PIN code by assigning a specific user ID. 

User ID: any number from 0 to 997 
PIN code: any number from 4 to 6 digits 

  (Digit user ID) 

  (Digit PIN code) 

 

Exit Setup Mode 

 

 

Add a card / tag by assigning a specific user ID 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

 

(Digit Master Code) 

 

Add card / tag by assigning a specific user ID.  

User ID: any number from 0 to 997 

 (Digit user ID) 

  (Read card) 

 

 

Exit Setup Mode 

 

 

Add one or more cards / tags using the "Master Add Card" provided

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

Read “Master Add Card” on the reader

 

Add on or more card  

Read one or more cards on the reader 

 

Exit Setup Mode 

Read “Master Add Card” on the reader 

 

Remove users 

 

Remove a card / tag through the card / tag itself

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

 

(Digit Master Code) 

 

Remove a card throught the card itself 

 (Read card) 

 

Exit Setup Mode 

 

 

Remove a card / tag or PIN code through the user ID

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

 

(Digit Master Code) 

 

Remove a card / tag or PIN using the user ID 

 (Digit user ID) 

 

Exit Setup Mode 

 

 

Remove all users

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

 

(Digit Master Code) 

 

Remove all users 

 

(Digit Master Code) 

 

Exit Setup Mode 

 

 

Remove one or more cards / tags using the "Master Delete Card" provided

 

Working descrip on

 

Keystroke combina on

 

Entering the programming mode 

Read the "Master Delete Card" on the reader

 

Remove one or more cards / tags  

Read one or more cards on the reader

 

Exit Setup Mode 

Read the "Master Delete Card" on the reader

 

tecnoautomation

T.A. Tecno Automazione s.r.l.

 - Via Vicinale snc - 03018 - Paliano - (FR) - Italy - Tel +39 0775 533677 - Fax +39 0775 533299 - [email protected]

www.tecnoautomation.com 

-

 www.tecnoautomazione.com

Summary of Contents for TASFD6T

Page 1: ...dual channel Standalone Wiegand tecnoautomation T A Tecno Automazione s r l Via Vicinale snc 03018 Paliano FR Italy Tel 39 0775 533677 Fax 39 0775 533299 info tecnoautomazione com www tecnoautomation...

Page 2: ...The device allows access through the use of an access code a card tag or a card tag in combina on with an access code or an input management through a bluetooth applica on compa ble with all smartpho...

Page 3: ...u on alarm Relay Relay closing me Adjustable from 1 to 99 seconds Maximum load 2 Amp Wiegand interface 26 bits Opera ng temperature 40 C 60 C Opera ng humidity 0 RH 98 RH Material Zinc alloy IP protec...

Page 4: ...and ANY DEVICE through the NO NC contacts and to use auxiliary command and or alarm func ons directly from the TASFD6T device page 5 Wiegand mode allows the TASFD6T to switch NO NC contacts to command...

Page 5: ...or opening the lock input ex internal exit bu on Grey Output_Alarm Nega ve contact for Alarm Voltage 12 28 Vac dc 2 A Brown Sensor Opening sensor input Normally closed WARNING In Standalone mode if th...

Page 6: ...from 4 to 6 digits Digit user ID Digit PIN code Exit Setup Mode Add a card tag by assigning a speci c user ID Working descrip on Keystroke combina on Entering the programming mode Digit Master Code A...

Page 7: ...de Default Op on 1 programming Select relay opening closing with ONLY card tag detec on Working descrip on Keystroke combina on Entering the programming mode Digit Master Code Select relay opening clo...

Page 8: ...de BISTABLE Working descrip on Keystroke combina on Entering the programming mode Digit Master Code Bistable mode Set the relay opening closing in ON OFF mode Exit programming mode Set jamming mode Th...

Page 9: ...larm OFF Working descrip on Keystroke combina on Entering the programming mode Digit Master Code Alarm OFF Warning this opera on will disable the blinding with alarm mode Exit Setup Mode Working descr...

Page 10: ...ts and consequently to enable any device connected to it In order to use the Wiegand mode of the TASFD6T keypad it is necessary to connect it to a remote decoder board WARNING Before being able to add...

Page 11: ...d tag through the card tag itself Working descrip on Keystroke combina on Entering the programming mode Digit Master Code Remove a card throught the card itself Read card Exit Setup Mode Remove a card...

Page 12: ...zzer OFF Opera on Keystroke combina on Enter the programming mode Digit Master Code Buzzer OFF Exit programming mode Buzzer ON Deafult Opera on Keystroke combina on Enter the programming mode Digit Ma...

Page 13: ...Digit Master Code Remove all users Digit Master Code Exit programming mode Warning this opera on will delete the Master Add Card and the Master Delete Card To restore the factory func ons it is neces...

Page 14: ...ices at a me WARNING The Master Unit and the Accept Unit must be TASFD6T The Master Code of the two units must be the same Perform the transfer opera on as below only on the Master Unit Perform the tr...

Reviews: