www.tecnaonline.com - [email protected]
E N G L I S H
6
MOUNTING THE HYDRAULIC BREAKER
PAR
DESCRIPTION
6.5
MOUNTING
DANGER OF MATERIAL DAMAGE AND PERSONAL INJURIES!
Fan incorrectly mounted hydraulic breaker can cause considerable damage to property and
persons. An incorrectly fastened hydraulic breaker can move in an uncontrolled manner and
damage other equipment.
»
Basic mechanical and hydraulic knowledge is necessary for mounting the hydraulic breaker.
The hydraulic breaker may be mounted only by qualified personnel (see section "2.2
QUALIFICATION
OF THE PERSONNEL” on page 5).
»
Ensure that the hydraulic hammer is fastened securely.
DANGER DUE TO USAGE OF AN INCORRECT HYDRAULIC BREAKER RANGE!
Mounting an incorrect hydraulic breaker range can lead to uncontrolled actions and injure persons
or damage the hydraulic breaker and / or the support frame.
»
Check whether you are using the correct hydraulic breaker on the basis of the model name on
the identification plate.
»
Check the scope of delivery for completeness.
»
Check the scope of delivery for possible damage due to transportation.
»
Check whether the operating manual is suitable for the hydraulic breaker.
1. You must ensure that the surroundings are clean before mounting and removing so that dirt
does not enter the oil circuit. Only use nonlinting fabric or speciality paper for cleaning purposes.
2. Bring the jib of the support frame in an optimal position so as to hold the hydraulic breaker with
the quick-changer.
3. Hold the hydraulic breaker with the quick-changer.
Have a sufficiently big collection container, enough cloth and mediumbinding materials
ready to collect or absorb the hydraulic oil coming out.
Follow the instructions of the quick-changer manufacturer.
DANGER
DANGER
OPERATING MANUAL
-
H
ydraulic
breakers
T
series
18
/44
REV
0.0
MOUNTING THE HYDRAULIC BREAKER
6