![TechWind SDK-500 User Manual Download Page 16](http://html1.mh-extra.com/html/techwind/sdk-500/sdk-500_user-manual_1070976016.webp)
User's manual for
4.2.
EDITING PARAMETERS
To edit any of the programming parameters select its name using
[<] [>]
buttons and
press
[ENTER]
.
4.2.1.
Numeric parameters
Numeric parameters are displayed as decimal numbers. Use buttons
[<]
,
[>]
to
increment or decrement selected (flashing) digit. Short pressing of the
[ENTER]
button moves
the selection to next digit.
Pressing
[ENTER]
at least 2 seconds (or pressing short after last digit) causes in
displaying confirmation question (message
”Save changes?”
). Select the answer (
„YES”
or
„NO”
) using
[<]
,
[>]
buttons and confirm selection by short pressing
[ENTER]
button.
4.2.2.
Switch parameters
Switch parameters can be described as a sets of values (a lists) out of which only one of
the options available on the list can be selected for the given parameter. Options of switching
parameter are selected using
[<]
,
[>]
buttons.
Short pressing of
[ENTER]
displays confirmation question (message
”Save changes?”
).
Select the answer (
„YES”
or
„NO”
) using
[<]
,
[>]
buttons and confirm selection by short
pressing
[ENTER]
button.
Functions of buttons when editing numeric and switching parameters
While editing numeric parameters – change of current (flashing) digit. While
editing switch parameter – selection of switch parameter.
If numerical parameter is being edited, a short press of
[ENTER]
button
change edited position. A long press of
[ENTER]
button (at lest 2 sec.)
causes of display a
”Save changes?”
ask. If switch parameter is being
edited, a short press of
[ENTER]
button causes of display a
”Save
changes?”
ask. Pressing
[ENTER]
button again (while
”Save changes?”
is
displayed) the answer selected by
[<]
,
[>]
buttons is confirmed.
Abandon entered (not confirmed) changes and go back to menu.
16
ENTER
ESC
MENU