![Techsage Spinjet 6200 Operator'S Manual Download Page 16](http://html1.mh-extra.com/html/techsage/spinjet-6200/spinjet-6200_operators-manual_1070870016.webp)
-
OPERATORS MANUAL
Page 16
Please check the Printer Display for any information or refer to
section “Troubleshooting” for directions. Whenever the SPINJET is
tilted down it will change to ‘Info’ mode immediately.
Push button on SPINJET
The ‘Standby’ button located on the SPINJET keypad has two
functions:
Switch from ‘Ready’ to ‘Standby’ mode.
This is done by pressing the button for less than 2 seconds.
(Function suppressed while printing.)
Reset.
Pressing the button for more than 2 seconds cancels printing
on the reverse side.
When printing jobs according to the requirements listed in section
“Job Requirements”, it will normally not be necessary to give any
inputs to the Control Panel at all, as single- or double-sided printing
is identified automatically by the system.
Please Note:
For normal, automatic operation it is important that
the SPINJET Control Box is switched ON while the Printer is ON in
order to monitor and react to the jobs flowing to the Printer.
5. Job Requirements
Two prerequisites have to be fulfilled in order to output a double-
sided print on SPINJET 6200:
The files front- and back side must have identical
geometrical size.
The files must be sent to the SPINJET from an application, RIP or
interface that supports the SPINJET. Possible methods available
at present are listed below.
TechSage has a two-legged interface strategy:
User interface via the SPINFLOW interface
Direct integration by the vendors of Prepress Workflow Systems
(RIPs).
5.1 SPINFLOW
SPINFLOW is the enhanced data interface between host Pre-Press
Systems and the HP Designjet Z6200 and Z6100 Series range of
large format colour printers hosting the SPINJET 6200.
Please refer to the SPINFLOW manual.
5.2 OEM RIP integration
The SPINJET system has been integrated in several prepress
workflow systems and more system providers are currently testing
the integration of the SPINJET into their workflow system. Please ask
you workflow system provider if the SPINJET is supported by their
solutions.
6. Troubleshooting
In case of any doubt regarding the general source (TechSage
SPINJET system or HP Designjet system) of a problem encountered,
do the following:
Set DUPLEXER to NO (refer to
Section
4.1 Printer Set Up
), turn
off
the SPINJET and move it to lower position. Send jobs using single
side, but otherwise similar to the trouble condition, to the Printer and
check whether the problems persist.
In the case the failure or damage is attributable to the HP Designjet
Printer the contact is HP Support Organization.