Annex E DUT-E S7 Radiobox RS firmware upgrade
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
80
Annex E
DUT-E S7 Radiobox RS firmware upgrade
WARNING:
firmware update should be carried out
only
for
implementing improvements, recommended by the
To upgrade firmware the following actions should be made:
1)
Connect DUT-E S7 Radiobox RS to the PC using
WARNING:
When
re-uploading
firmware,
power
supply
voltage
of
DUT-E S7 Radiobox RS should not drop out of 9
…45 V range
.
2)
After authorization press
button in Service S6 DUT-E software.
3)
Choose firmware upgrade file
(*.blf3)
on PC disk or memory stick.
4)
Press
button, that will start firmware file downloading into DUT-E S7 Radiobox RS
memory.
After firmware file integrity and compatibility check by Service S6 DUT-E software window of
firmware uploading into DUT-E S7 Radiobox RS memory will appear. In case of any errors the
software will send warning message.
To cancel firmware upgrade it is needed to press
button.
ATTENTION:
Before the end of the update process and automatic Service S6 DUT-E
software reset it is
forbidden
:
•
power down the PC;
•
power down the DUT-E S7 Radiobox RS;
•
disconnect DUT-E S7 Radiobox RS from the adapter and adapter from the PC;
•
run any resource-intensive applications on the PC.
Service S6 DUT-E software will display appropriate message and automatically will disconnect
DUT-E S7 Radiobox RS from PC in case the update is successful. DUT-E S7 Radiobox RS is
ready for further operation.
Service S6 DUT-E software will display a new firmware version with the next connection
session between PC and DUT-E S7 Radiobox RS.
If the DUT-E S7 Radiobox RS firmware update has been completed incorrectly and the current
version of the inbuilt software has been damaged, the firmware update procedure has to be
repeated. In this case, the inbuilt firmware loader is activated which enables to recover
DUT-E S7 Radiobox RS operability. If the repeated attempt fails, we recommend to consult