Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Base S7 FM
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
78
D.5 Base S7 FM
—
is designed for reception of messages (
by means of
Figure D.6
—
Example of the window of settings of Base S7
in Service S6 DUT-E software for DUT-E S7 Radiobox RS
Table D.5
—
Base S7. Displayed and/or editable SPN
with the help of Service S6 DUT-E software
SPN
Name
Factory value
Unit of
measure
Clarification
Available Bluetooth Device List
Array Elements
Count
On the fact
pcs.
The number of MAC addresses of wireless Units (
sensors) which are visible (accessible) at a current moment for
BLE-module of
The maximum number of elements in the list
—
15.
The list is not accessible for editing.
MAC Address
On the fact
No
The setting displays the unique identifier (MAC address) of
BLE-module of the wireless Unit.
Using MAC address, the software generates a serial number of a
specific Unit and also identifies its accessibility status for operation
based on S7 Technology.
The data are not accessible for editing.
Received Signal
Strength
Indicator (RSSI)
On the fact
dBm
The setting displays the current level of the signal power (by the
logarithmic scale) received from the wireless Unit.
The displayed range: from -
125…0 dBm.
The data are not accessible for editing.
Timeout
On the fact
s
The setting displays the length of the time interval after reception of
the latest message from the wireless Unit.
The data are not accessible for editing.
Allowed Units S7 List
Array Elements
Count
On the fact
pcs.
Number of MAC addresses of wireless
sensors) selected by the user, in order to establish communication
with DUT-E S7 Radiobox RS using
The maximum number of elements in the list
—
2.
The user has access to editing the list (addition/deletion of Units).