![Technoton DUT-E S7 Operation Manual Download Page 56](http://html.mh-extra.com/html/technoton/dut-e-s7/dut-e-s7_operation-manual_1070695056.webp)
DUT-E S7 Radiobox RS wireless interface / Electrical connection
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
56
Figure 29
—
electrical connection
Table 8
—
Designation of wires in
OUT
wire bundle
Connector
Pinout
Connector
Contact
Number
Wire Marking
Wire Color*
Circuit
Designation
Signal
Parameters
S6 Mol
1
VBAT
Orange
Power “+”
Analog,
voltage
9…45 V
2
GND
Brown
Ground “
-
”
—
5
KLIN
Black
K-Line
Digital,
ISO 14230
Standard
—
TX
Blue
Data transmitted
Digital,
RS-232
Standard
RX
White
Data received
B
Blue
Exchange of data
Digital,
RS-485
Standard
A
White
Exchange of data
*
reserves the right to modify wire colors, that is why pay attention to its markin.