DUT-E S7 Radiobox RS wireless interface / Design
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
51
7.3 Design
1
–
casing inside which there is the BLE-module designed to receive data from
DUT-E S7
, the electronic unit for processing the data
and the non-volatile memory to save user settings;
2
–
wire bundle
OUT
designed for operational connection and service connection;
3
–
S6 Mol
service connector (
KLINE
wire (black) for configuration,
VBAT
(orange) and
GND
(brown) wires for power supply connection);
4
–
TX
(blue) and
RX
(white) wires for connection to the
via RS-232 interface;
5
–
B
(blue) and
A
(white) wires for connection to the Telematics terminal
via RS-485 interface.
Figure 27
—
design
3
4
5
2