![Technoton DUT-E S7 Operation Manual Download Page 72](http://html.mh-extra.com/html/technoton/dut-e-s7/dut-e-s7_operation-manual_1070695072.webp)
Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Self-diagnostics FM
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
72
SPN
Name
Factory value
Unit of
measure
Clarification
Line
DUT-E
No
Name of the product line.
The line represents a group of similar products
–
fuel level sensors
produced under general trademark
SPN is not available for editing.
Mark
TECHNOTON
No
Name of the Unit Manufacturer.
SPN is not available for editing.
Firmware
version
On the fact
No
Version of built in Software of the
SPN is not available for editing.
Date of
production
On the fact
No
Date (day, month, year) of the Unit production.
SPN is not available for editing.
Address at
S6 (SA) bus
129
(for DUT-E S7
Radiobox RS)
101/102
(for DUT-E S7)
No
Network address of the Unit.
Values of unique network addresses are automatically set by the
service software and are not accessible for editing by the user.
Unit. Counters
Unit working
time
On the fact
s
Counter of summarized working time of the Unit since its
production moment.
The user cannot reset the value of this counter. It can be reset by
the
only.
Number of
Unit restarts
On the fact
pcs.
Counter of Unit
’s processor restarts at a time when the power is
On or there is an impact of conducted interferences of the
vehicle’s
on-board network. Restarts accounting is carried out
since production date of the Unit.
The user cannot reset the value of this counter. It can be reset by
the Manufacturer or RSC only.
Unit. Passwords
/3.3
Password/
3.3 Installer
1111
No
Password is entered for user authorization while establishing
connection session between DUT-E S7 Radiobox RS and service
Software for configuring the Unit.
Password is a specific combination of four digits.
By default, used:
Login
–
0, password
–
1111.
User can change password of the Unit.
After entering and confirming the new password is recorded into
internal memory of the Unit.
Active DTC
Malfunction
code (SID)
On the fact
No
List of current Unit malfunctions are displayed at the settings field
(in case of its presence
—
up to 10).
For each active malfunction is indicated following:
- faulty nod;
- malfunction name.
This setting allows to monitor Unit working performance.
In case of lack of active malfunctions, the following message is
displayed “No malfunctions”.
Bootloader information
Bootloader
Version
On the fact
No
Displays current version of the bootloader used for the correct start
of service software, as well as when updating firmware of the Unit.