VarioSelectCDE 18-27 TECHNOTHERM
6
Installation site
•
Appliance must only be installed in frost-free rooms. Never expose appli-ance
to frost.
•
The Appliance must be wall mounted and has to be installed with water
con-nectors downward.
•
The appliance complies with protection type IP25 and may therefore be instal-
led in protection zone 1 according to VDE 0100 part 701.
•
In order to avoid thermal losses, the distance between the instantaneous water
heater and the tapping point should be as small as possible.
•
For maintenance work, a shut-off valve should be installed in the supply line.
The appliance must be accessible for maintenance work.
•
Plastic pipes may only be used if they conform to DIN 16893, Series 2. The hot
water pipes must be thermally insulated.
•
The specific resistance of the water must be at least 1100 Ω cm at 15 °C. The
specific resistance can be asked for with your water distribution company.
5. Installation
•
The following regulations must be observed:VDE 0100
•
EN 806-2
•
Installation must comply with all statutory regulations, as well as those of the
local electricity and water supply companies.
•
The rating plate and technical specifications
•
Only intact and appropriate tools must be used