VarioSelectCDE 18-27 TECHNOTHERM
8
5. Installation
Note: If you install this instantaneous water heater in exchange for a conventional
instantaneous water heater, there is generally no need to drill holes for the wall
bracket, in this case step 2 would not be necessary.
Thoroughly rinse the water supply pipes before installation to remove soiling from
the pipes.
1.
Using a 12 mm hexagon socket screw key, screw the screw-in nipples into the
wall connections. The seals must be fully screwed into the thread. After tigh-
tening, the double nipples must protrude by at least 12 mm.
2.
Hold the included mounting template on the wall and align it so that the holes
in the template fit over the connections. Mark the drill holes accord-ing to the
template and drill them using a 6 mm drill. Insert the included dowels.
3. Screw in the wall bracket. Offset tiling or uneven surfaces can be compensated
by up to 30 mm with the aid of the spacers supplied. The spacers are fitted
between the wall and the wall bracket.
Installing the wall bracket