Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.23
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Carry out the
Standard Settings
procedure as detailed in the relevant paragraph of the Service
menu.
(2)
Check that the mechanical system, consisting of the pedals, belt and brake, moves smoothly
and without higher than normal friction or resistance.
(3)
Measure the voltage supplied by the Brake Board to the winding. In Quick Start mode, select
the effort level and check that the value is different from 0.
If you replace Brake Board, check that its SW version is updated, otherwise install the
last version.