Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.37
6.15.
THE TELEMETRIC HEART RATE SIGNAL IS INCORRECT
6.15.1.
C
HEST
B
ELT
CORRECT USE OF THE CHEST BELT: Wear the chest belt take care the area of
contact with the body is humid in order to guarantee it proper works.
THE TELEMETRIC HR
SIGNAL IS INCORRECT
(Chest belt)
Are the machines correctly
spaced by the required minimum
distance?
Check the Receiver Board has
been correctly mounted on the
machine.
Reposition the machines
so they are adequately
spaced
Mount the Receiver
Board in the right way
NO
YES
NO
Check the Display SW
versione and the grounding of the
receiver.
1
2
Chest belt defective
NO
NO
YES
A
Check if it works properly using
a chest belt you are sure it's ok.
The problem persists?
3
YES
Continued on following page....