Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.14
2
NO
Is the v oltage at the input
of the Brake Board
correct?
NO
YES
Replace
CU312 cable
NO
Replace the power
entry module
YES
Check if there are the
v oltages at the output of
the Brake Board.
YES
Replace the
Brake Board
4
B
Check if there are the
v oltages at the input of the
CPU Board.
Replace
CPU Board
NO
YES
5
3
Is the v oltage at the
output of the power entry
module correct?
Replace the
connecting between
High Kit and Low Kit
NO