Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.19
6.9.
MESSAGE ON DISPLAY “THE EQUIPMENT IS LOCKED
(COM)”
This error message can be caused by loss of communication between the High Lit and Low Kit and
a 'possible interruption during SW loading/upgrade.
The error is displayed by a massage and stored in the “
Errors Log
” section.
To reinstate communications between the lower and upper assemblies:
(1)
Check that cable
CU69
and
CU63
are correct, using the
Test Box Excite
and replace if
necessary.
(2)
Try replacing the Brake Board and the CPU/ARM Board in turn, and check whether the
communication works.
If you replace Brake Board, check that its SW version is updated, otherwise install the
last version.