Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 8.4
8.4.
ALIGN THE BELT CONNECTING THE PRIMARY AND
SECONDARY SHAFTS
Figure 8.4-1
Carry out the operations described in
paragraph: 7.7. “Disassembling the guards” for
disassembling the front guard.
1.
Check that the pulley on the primary shaft is
aligned with the sprocket on the secondary
shaft using a straight reference rod, and
adjust the bridge bearings if needed, moving
them sideways inside the slots on the frame.