6.3.4 VALUES DISPLAY FOR MONITORING
Press and hold buttons and simultaneously for 4 seconds or longer to display values.
Use temperature setting buttons and to display the alarm item code (see table below).
To return to normal display, press button .
Item code
Sensor type
Remark
From A2 control board
00
Water temperature for control
Not used
01
Remote control temperature
Not used for heat pump control
02
Water temperature control (TW)
03
Liquid line (in cooling) temperature (E1)
04
Heat exchanger temperature (E2)
Temp. calculated from pressure
05
Heat exchanger temperature (E3)
Not used
06
Discharge air temperature
Not used
07
Not used
08
Not used
09
Not used
From A3 control board
0A
Compressor discharge temperature (TD)
0B
Not used
0C
Not used
0D
Compressor suction temperature (TS)
0E
Air heat exchanger temperature (C1)
0F
Air heat exchanger temperature (C2)
10
Not used
11
Outdoor temperature (TO)
12
Not used
13
Not used
14
Compressor current - A
15
Valve position - step
16
Not used
17
Not used
18
Not used
19
Compressor operating frequency - Hz
> = 1A
Not used
Values display -
example
Measured value : 480 steps
Value item code “15” corresponds to
expansion valve position (steps)
Summary of Contents for PHIE 095
Page 2: ...2...
Page 10: ...10...
Page 11: ...11...
Page 12: ...12 1 3 2 THREE PHASES MODELS...
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...
Page 17: ...17 1 4 PHYSICAL CHARACTERISTICS...
Page 18: ...18...
Page 19: ...19 1 5 DESCRIPTION 1 5 1 SINGLE PHASE MODELS...
Page 20: ...20 1 5 2 THREE PHASES MODELS...
Page 22: ...22...
Page 23: ...23...
Page 31: ...31 2 1 FRIGORIFIC HYDRAULIC DIAGRAMS 2 1 1 DIAGRAMS FOR MODELS 095 125 155 157 175 177 195 197...
Page 32: ...32 2 1 2 DIAGRAMS FOR MODELS 257 307...
Page 34: ...34 Connection diagram for 155 175 195 Connection diagram for 157 177 197 257 307 257 307...
Page 43: ...43 Failure matrix...
Page 44: ...44 Failure handling...
Page 49: ...49 3 1 ELECTRICAL DIAGRAMS 3 1 1 MODEL 095 2 HP 230V Single phase...
Page 50: ...50 3 1 2 MODEL 125 3 HP 230V Single phase...
Page 51: ...51 3 1 3 MODELS 155 175 4 5 HP 230V Single phase...
Page 52: ...52 3 1 3 MODEL 195 6 HP 230V Single phase...
Page 53: ...53 3 1 3 MODELS 157 177 197 4 5 6 HP 400V Three phases...
Page 54: ...54 3 1 3 MODELS 257 307 8 10 HP 400V Three phases...
Page 55: ...55 3 1 4 SYMBOLS...
Page 57: ...57 3 2 2 CONTROL SYNOPTIC FOR HEAT PUMP IN BOILER BACK UP APPLICATIONS...
Page 65: ...65 A3 board A086VH up side FOR UNIT 125 HIC temperature sensor plug Power LED EEPROM LED...
Page 77: ...77 A4 Supply and filter board for units 257 307...
Page 101: ...101 For models 257 307...
Page 104: ...104 For models 095 125 Replace A3 PCB...
Page 105: ...105 For models 155 157 175 177 195 197...
Page 106: ...106 For models 257 307...
Page 107: ...107 For models 095 125...
Page 108: ...108 For models 155 157 175 177 195 197 Check diode bridge...