After pressing the menu icon, the user sees a review of cards with particular functions. In order to enter editing of the selected
parameter, touch the icon symbolizing this function. Touch again to move to the settings change screen. Any changes introduced
are confirmed after touching any place on the screen or the confirmation icon:
PARTY
After activating the
PARTY
mode, water in the heat pump's tank reaches the preset temperature as fast as possible. After this
mode is activated, all available heat sources will be switched on.
HEATER
After this operation mode is activated, only the heater will operate.
LEGIONELLA
Thermal disinfection means that temperature will be increased to the necessary disinfection temperature of min. 60°C througho
ut
the entire hot water circulation.
New regulations impose the obligation to adjust the installed tank system to periodical thermal disinfection conducted at a water
temperature not lower than 60°C (recommended temp. 70°). A
ll ducts, fittings and the full technological system for hot water
preparation must undergo disinfection to fulfill this requirement.
Main
menu
Party
Heater
Legionella
Operation mode
Clock settings
Date settings
Preset tank temperature
PV preset temperature
Anti-freezing
Weekly schedule
Legionella schedule
Circulating pump
Detalis screen
Screen settings
Software information
Safeguards
Language
Ethernet module
Amount of generated energy
Service time
Service menu
ZAPISZ NA PENDRIVE
Stand-by
Summary of Contents for ST-53.4
Page 1: ...ST 53 4...
Page 6: ...6 ST 53 4...
Page 9: ...9...
Page 25: ...25 www tech controllers com 53 4 USER MANUAL...
Page 28: ...28...
Page 44: ...44...