Te Pari T10 Manual Download Page 10

10

Scale Indicator Manual 917-5

Arrow to 

DRAFTING

 in the 

MAIN MENU

 and press 

RECORD/SELECT

Arrow down to and key in the weight ranges 
you wish for your draft gates. Ensure the highest 
weight set is more than the heaviest animal likely 
to be weighed.

Arrow to 

Save and Exit

  and press 

RECORD/

SELECT

 to return to the 

MAIN MENU

.

Further Information:

Draft by options are either 

Draft by Weight

Draft 

by Code 

or 

OFF

. This field is already highlighted 

when the screen opens. The draft by code option 
is only available when enabled, to do this: On the 

Recording

 screen set 

Tag Recording

 to 

ON

 then; 

Enter the 

Code Recording

 options screen and set 

Code 1

 to 

ON

The hold column is only shown when 

AUTO DRAFTING 

is the active option on the 

Connections

 screen. You can set hold for each 

gate to either 

ON

 or 

OFF

.

When a gate has hold set to 

ON

 the draft is held 

until the 

RECORD/SELECT

 button is pressed.

While held you can arrow to any entry on the 
main screen and adjust its properties. This 
lets you make on the fly decisions based on 
observations during your session.

AUTO EID: 

This assigns a false EID number to an animal that 
has a damaged or missing tag. Options are 

OFF

 or 

a delay time of 

5s

10s

20s

 or

 30s

.

10s

 is the default option.

The delay sets the amount of time a tag read is 
unsuccessful before a false EID is assigned.

D R A F T

 

Gate 

CODE 

C0 

OFF

Gate 

CODE 

C1 

OFF

Gate 

CODE 

C2 

OFF

Gate 

CODE 

C3 

OFF

Gate 

CODE 

C4 

OFF

Gate 

CODE 

C5 

OFF

Gate 

CODE 

C6 

OFF

Gate   8 

CODE 

C7 

OFF

Gate 

CODE 

OFF

Gate   0  EID not read

Gate   0 

OTHER

AUTO EID:  OFF

Save and Exit

D r a f t   R a n g e s

D r a f t   b y   -    

C o d e

 

Gate 

0000.0    - 

0050.0 

OFF  

 

Gate 

0050.1    - 

0070.0 

OFF 

Gate 

0070.1    - 

0090.0 

OFF 

Gate 

0090.1    - 

0300.0 

OFF 

Gate 

0000.0    - 

0000.0 

OFF 

Gate 

0000.0    - 

0000.0 

OFF 

Gate 

0000.0    - 

0000.0 

OFF 

Gate   8 

0000.0    - 

0000.0 

OFF 

Gate 

0000.0    - 

0000.0 

OFF 

Gate   0 

EID not read

AUTO EID:  10s

Save and Exit

D r a f t   R a n g e s

D r a f t   b y   -    

W e i g h t

Set your Draft Ranges on a T20 scale indicator

Summary of Contents for T10

Page 1: ...de Te Pari Scale Indicator Manual www tepari com Covering T10 and T20 models including E series Te Pari Direct Support USB Card Installation and use of Te Pari Connect and Downloader Software Te Pari...

Page 2: ...tery D USB Wi Fi dongle plugs into a USB port on your PC to connect to your scale using Wi Fi E Te Pari scale mounting bracket and 2x U bolts for fixing the bracket to a post if required F 12 Volt pow...

Page 3: ...scale indicator 16 Connecting using Wi Fi 16 Direct cable connection to your PC or device 17 Connecting to a PC or device using Bluetooth 18 Getting the latest software for your scale using your Te P...

Page 4: ...ed cable COM ports COM1 and COM2 Both plug styles are shown here These attach the scale to other devices like computers etc Each port uses a different address so if one won t connect you may need to t...

Page 5: ...main working area TALLY FILENAME STOCK B EID VID FAST1 REC CODE1 DRAFT PREV WGT IVOMEC TOT GAIN DRENCH ml ml 95 0KG 9 2 1 0000 0 0000 0 15 0087 Health dosage 2 display area When Health Mode 2 is off...

Page 6: ...right arrows change the items setting The term arrow to in this guide refers to using the arrows to select or change an item using the arrow buttons The RECORD SELECT button is used to confirm your se...

Page 7: ...Bluetooth PHONE COMPUTER Loadbar Model T1000 Description Te Pari DR3 Drafter Gate 1 0000 0 0050 0 OFF Gate 2 0050 1 0070 0 OFF Gate 3 0070 1 0090 0 OFF Gate 4 0090 1 0300 0 OFF Gate 5 0000 0 0000 0 O...

Page 8: ...Usually Com Plug 1 is set to PHONE COMPUTER Arrow to Loadbar Model then use the left and right arrows to select your correct loadbar model from the list It is important that this is set correctly for...

Page 9: ...or OFF When set to ON the Starting at number field is shown and you can key in your preferred starting number The VID number issued increases from your starting number by 1 each time one is assigned...

Page 10: ...ELECT button is pressed While held you can arrow to any entry on the main screen and adjust its properties This lets you make on the fly decisions based on observations during your session AUTO EID Th...

Page 11: ...orth between them Running a What if scenario To see what happens to draft weights and quantities without changing your stored recorded data You can edit the weight ranges in the Wt Stats screen then s...

Page 12: ...T 00123456789 123456789 STOCKB H The Statistics screen Data columns in the Statics menu Use the left and right arrows to scroll across the data columns as shown here Arrow to DOSING in the MAIN MENU a...

Page 13: ...ATE EIDS Options are YES the default or NO If set to YES when a duplicate EID is scanned while autodrafting it will overwrite the duplicate record If NO it will stop and wait for operator confirmation...

Page 14: ...for each of your 4 main tasks You can then load them and tweak the settings from there to suit your sessions needs A loaded favourite will not change when you alter settings you need to overwrite the...

Page 15: ...described on page 22 Note Users of Windows 8 and above do not need to install the drivers as they are included with Windows so you can skip this step and can go to the top of the next page If your com...

Page 16: ...e iScale entry and click Connect Working with files is handled in your application Now the connection is made you can run Te Pari Downloader to view and work with your files or if using a smart phone...

Page 17: ...ial cable in to the Scales COM1 port Using the serial to serial cable Plug the other end of the serial to serial cable into a serial port on your computer Physical serial to serial connection is made...

Page 18: ...Te Pari applications and drivers for use with your scale and its components The URL for the support centre is also printed on the card so you can type it into your web browser to go there Current appl...

Page 19: ...oid or the Apple Store for Apple devices The screen shots shown in this guide are of the Android version Screens will vary depending on both the type of device you are using and the operating system i...

Page 20: ...ready to run the Te Pari Connect App Once launched it prompts you to tap start to continue From the App list tap the Te Pari Connect icon You are now prompted to either connect and download new record...

Page 21: ...re now prompted to provide a file name for the download the default name is the current date and time Tap save when finished All downloaded records on the device are listed Each file has a checkbox to...

Page 22: ...also tap the Upload Email file tab from the view window to send the file on To forward your files on select the files checkboxes that you wish to forward then tap the Upload Email Selected tab You wi...

Page 23: ...s send the email from Te Pari When done tap the back button You are returned to the What would you like to do screen Continue with another action or tap quit to exit then tap quit on the prompt Depend...

Page 24: ...displayed Click Finish to exit the installer and return to your desktop You will notice a Macrostock Lite icon on your desktop and also under Start All Programs in a MacroStock Lite folder You can run...

Page 25: ...whether or not you wish to go on the mailing list These same details also used when required when you forward data from the application Click the activate button The software will now be registered Th...

Page 26: ...the System main menu Click the Home tab to be returned to the home tab The Scale image with its connection type listed below it should now appear in the left of the menu bar The connection is now comp...

Page 27: ...gside A The Scale Downloader button Clicking this opens the files on the Scale in the usual working window B The Contacts button Clicking this opens the Contacts main area This is where you add and ed...

Page 28: ...on a column title sorts the displayed records by that title Clicking the small arrow alongside the title toggles the sort between ascending and descending You can remove unwanted columns by clicking...

Page 29: ...rds with XMD recorded in them and view a list of just these animals When done you can clear the filter with the same tool A B D C E A The Preview Export button When you click this the current file is...

Page 30: ...below and changes depending on the file type that you have selected see the example below F Contacts List Allows you to add and modify your contacts directly from this area G Displays a list of the r...

Page 31: ...h the menu bar Click on the Upload File button A to open the Upload File Screen shown below Click the Open File button B browse to the file you wish to upload select it C then click the Open button D...

Page 32: ...l be available for selection from the File List screen on your scale C D A B E Te Pari Downloader software Deleting a file on your Te Pari Scale Indicator The downloader software allows you to delete...

Page 33: ...33 Scale Indicator Manual 917 5 Notes...

Page 34: ...e 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Page 35: ...0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set Tag Recor...

Page 36: ...te 7 0000 0 0000 0 OFF Gate 8 0000 0 0000 0 OFF Gate 9 0000 0 0000 0 OFF Gate 0 EID not read AUTO EID 10s Save and Exit Draft Ranges Draft by Weight If you want weights only without recording tags Set...

Page 37: ...sing EID or visual tags and you want every tag read Set Tag Recording to ON RECORDING Recording Tag Recording ON Weight Gain Total Gain Auto Visual Tags ON Starting at number 0001 Code Recording OFF S...

Page 38: ...holes in the top of the load bars so the two pieces can be bolted together It is best not to have these bolts too tight An evenly levelled concrete pad of a size greater than the platform or crush is...

Page 39: ...ion Connect the load bars to your Te Pari indicator Turn on the indicator and press zero Place a test weight at one end of the platform and note the reading on the indicator The displayed weight shoul...

Page 40: ...40 Scale Indicator Manual 917 5 Te Pari Standard and Heavy Duty load bars 1000 mm Heavy Duty load bar schematic 600 mm Standard load bar schematic...

Page 41: ...is useful for quickly drafting or collecting statistics on a group of animals without recording any additional information EID status lights T20E model only Red Green Yellow SERVICE OK POWER Indicate...

Page 42: ...service provider Te Pari is not liable for any damages or personal injury caused by the product or the failure of the product to perform including any damage or loss of data on the product or computer...

Page 43: ...43 Scale Indicator Manual 917 5 Notes...

Page 44: ...274 Australia 1800 650 682 USA 800 315 0433 International 64 03 433 0077 Head Office 9 Endeavour Crescent P O Box 25 Oamaru 9444 New Zealand REV 917 7 www tepari com For more information on our full...

Reviews: