COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
75/79
2) Register Read
R eques t PDU
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Starting Address
2
202 (0x00CA)
Quantity of Registers
2
1 (0x0001)
R es pons e PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Byte count
1
2 (2 x 1)
Registers value
2
Reading data.
E rror PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 83
Exception code
1
0x02 / 0x04
3) Register Write
R eques t PDU
Write Holding.
Field
Byte
Value
Function code
1
0x 06
Starting Address
2
202 (0x00CA)
Registers value
2
writing data.
R es pons e PD U
Write Holding.
Field
Byte
Value
Function code
1
0x 06
Starting Address
2
202 (0x00CA)
Register value
2
echo query data.
E rror PD U
Write Holding.
Field
Byte
Value
Function code
1
0x 86
Exception code
1
0x02 / 0x03 / 0x04