![TDK-Lambda GXE600 Series Communications Manual Download Page 71](http://html2.mh-extra.com/html/tdk-lambda/gxe600-series/gxe600-series_communications-manual_4197170071.webp)
COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
71/79
2) Register Read
R eques t PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Starting Address
2
200 (0x00C8)
Quantity of Registers
2
1 (0x0001)
R es pons e PDU
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Byte count
1
2 (2 x 1)
Registers value
2
Reading data.
Error PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 83
Exception code
1
0x02 / 0x04
3) Register Write
R eques t PD U
Write Holding.
Field
Byte
Value
Function code
1
0x 06
Starting Address
2
200 (0x00C8)
Registers value
2
writing data.
R es pons e PDU
Write Holding.
Field
Byte
Value
Function code
1
0x 06
Starting Address
2
200 (0x00C8)
Register value
2
echo query data.
Error PD U
Write Holding.
Field
Byte
Value
Function code
1
0x 86
Exception code
1
0x02 / 0x03 / 0x04