21
Total Control Systems
www.tcsmeters.com
Pulser Type
Select the pulse input type (Single or Dual Channel) and press ENTER.
SINGLE is a single channel pulse input.
DUAL is a dual channel pulse input.
Chose FORWARD or REVERSE for the direction of flow.
QUAD is a dual channel pulse input multiplied by two.
Chose FORWARD or REVERSE for the direction of flow.
Pulser Estimate
Manual entry of the Meter Pulse Estimate (Meter Factor). Input pulse
value and press ENTER. USE ONLY FOR PRODUCT SETUP.
NOTE: The TCS 3000 register will not accept the entered Pulse Estimate until a
physical calibration is placed immediately after entry. See Edit Product Calibra
tion on page 23 for direct entry and acceptance.
Product Units
Select TCS 3000 register units of measure and press ENTER.
Volume: Highlight Volume Unit and press ENTER.
NOTE: Selecting Product Unit does not change the Totalizer unit of measure. See
Page 26 for changing Totalizer unit of measure.
Hose Volume
Enter unit volume value for “packing” hose downstream of meter and press
ENTER. Value will not display prior to setting and there will be no lost liquid. See Page
21 for Enabling this function.
To comply with Weights & Measures requirements, it is necessary to start and stop
each delivery with a fully packed hose. There are times where the hose is not fully
packed (e.g. after a preset delivery). As such, the hose must be packed and the regis-
ter zeroed prior to making the next deliver.
NOTE: This procedure will not work for an empty or dry hose. If more than 1 gallon or 5
Liters of liquid is required to pack the hose, a delivery ticket must be printed.
Maximum Pulser Error Program the amount of reverse pulse counts the register is allowed to see before it
shuts the system down. NOTE: Maximum value is 255.
Additive Injector
Injection Ratio How many parts per million will be injected into the product, calculated as Parts Per
Million (PPM).
Injector Type
NONE
No Injector
EXTERNAL
A constant positive signal output is provided during product delivery.
NOTE: An external additive Injector controls injection pump rate.
INJECTOR CALIBRATION
AI Pulses/Unit (Enter Pulses per mL)
AI Pulser Type - Dual or Single
INJECTION LIMITS - Enable/Disable Injection Limit for delivery shutdown.
Enter Minimum PPM value to end delivery
Enter Maximum PPM value to end delivery
Enter Additive Injection Stabilization Volume to stabilize the PPM ratio
at the beginning of a delivery.
GAL
USA Gallons
L
Liters
UKG
UK Gallons
daL
Dekaliter
mL
Milliliter
m3
Cubic Meter
bbl
Barrel