09/2013
13
TCS TürControlSysteme AG, TCS Hotline Germany: +49 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 41 94/ 9 88 129
Mail: [email protected]
PI_IMM2500 1A
Commissioning
Install the devices of the system completely.
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the main voltage.
Settings
Factory settings
Button assignment
basic module function key
control function 8
Module with special functions
button RED,
send control function 10
button YELLOW switching lights
button GREEN
send control function 8
Pre-adjusted times
communication time
max. 2 min
blinking period of the red LED, if
speech channel is busy when
pressing the speech button
3 sec
6 x blinking
internal standby time
around 2 min, if the device was called
around 30 seconds, if the device itself is calling
and waiting for call acceptance
motion detector
12 hours
Set the ring tone volume for door calls
can be adjusted continuously at the ring tone volume control (see device overview)
Set the sensitivity of the motion sensor
can be adjusted at the control for motion sensor sensitivity below the labelling of the
function keys
Set the control of the motion sensor sensitivity with a suitable screwdriver to the maxi-
mum sensitivity (clockwise until the stop). When unintended triggering is caused, reduce
the sensitivity by turning the controller counter-clockwise.
When installing the IMM2500 on a desktop accessory, the motion sensor must be deac-
tivated (off)!