8
Indication and operating elements
Term Function
LED is OFF
device is in basic mode, no error is detected
LED green
ON (lights up for 3 s)
∙ positive input confirmation
∙ code number accepted (can be deactivated, adjustable lighting duration)
BLINKS: device is in programming mode
LED red
ON (lights up for 3 s):
∙ wrong entry
ON (lights up for 2 min):
∙ locked (after the code was entered 3 x incorrectly)
ON (lights up permanently)
∙ entry master code
LED orange
FLASHES: total error indication
bell button
trigger a door call
code lock keypad
operation, programming of code lock functions
∙ numeric buttons from 1 to 0
∙ #-button: light switching in basic mode, input confirmation in program-
ming mode
∙ *-button: entry of command sequences and abort of incomplete com-
mand sequences in programming mode
Technical data
supply voltage
+24 V ± 8 % (power supply and control unit)
material of the housing
aluminium
colour of the housing
anodised natural
nameplate glass
acrylic glass, printed, 5 mm thick
dimensions (in mm)
housing
H 242 to 318
x W 135 x D 20
camera field
H 38 x W 82
camera
colour camera
CMOS sensor, 380 TVL
light
sensitivity
0 lux (IR on), 1 lux (IR off);
automatic daytime / nighttime operation
focal length f
2.0 mm (F = 2.5)
diagonal
detection
angle
130°
video output
1 Vpp, symmetric, 1 Vss FBAS
acceptable ambient temperature
-20 ...+ 50 °C
input current in resting position (6-wire
operation)
I(a) = 0.6 mA
I(P) = 80 mA
maximum input current
I(Pmax) = 100 mA