Connecting the lines
acceptable cross section (diameter)
0.08 … 0.82 mm2 (Ø 0.32 … 1.0 mm)
maximum number of wires per terminal contact
2 x 0.8 mm, 3 x 0.6 mm
Connect further wires by using auxiliary terminals.
Use only connecting lines made of the same material and with the same diameter within one terminal
contact.
Detailed information on wire routing in TCS systems as well as on the loop resistance you'll find in the
system manual. Available under: http://www.tcsag.de/download/kataloge-prospekte-flyer
CAUTION!
Device damage.
Use the small slot screwdriver (enclosed in the delivery) to connect lines. Avoid damaging the device.
CAUTION!
Device damage.
The inner resistance of the door opener must not fall below 6 Ohm!
►
Strip the cable ends.
►
Connect the wires according to the connecting diagram depending on the type of system.
Do not place the wires in front of the LEDs. Otherwise this might affect the name plate illumination nega-
tively. Ensure that the wires are not getting clamped below the spacers at the rear side of the front door
station.
Connect the floor push-button
►
Connect the floor push-button to the terminals E and P.
Alternatively you can connect the floor push-button to the terminals a and E.
Ensure that the a-wire of the power supply and control unit is connected to the a-terminal of the indoor
station.