Bell button programming 

Basic principle 

All devices at the TCS:BUS have an unique serial number.  
The serial number of the indoor station is allocated to the bell button of the front-door station. The allocation is 
stored in the EEPROM of the front-door station.  
 
Requirements for the programming: 

 

Ensure that the access to the indoor station in the flat is granted. 

 

Check if the indoor station is connected to the TCS:BUS. 

 

Switch on the mains voltage. The operating LED at the power supply and control unit is on. 

 

Check if no programming lock is set. 

 

 

Before you can reprogram an already programmed bell button, you have to delete the programming. 

 
 

Legend 

press button shortly 

 

busy tone 

 

Press the button until... 

a negative acknowledgement tone sounds 
(bell button is already programmed) 

 

release the button 

 

SNapp-tone 

 

go on 

 

NoProg-tone (negative acknowledgement 
tone) 

 

ring tone 

 

deletion tone sequence 

 

Progsperr-tone 

 

Prog2-tone (programming of the 2nd serial 
number starts) 

 

 

 

Audio files of the call and acknowledgement tones are available online at: www.tcsag.de/download/ruf-
und-quittungstoene 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AVD Series

Page 1: ...Product information Front door station series AVD AVE with integrated code lock...

Page 2: ...nectingthelines 10 Connectthe floorpush button 10 Examplecircuit 11 Commissioningvideo 11 Extendedcodelock function 12 Initialoperation 12 Connectthe floorpush button 12 Settingthevolumeofmicrophonean...

Page 3: ...lease in basic mode 21 Switching the lightinbasicmode 21 Repair 21 Exchanging the EEPROMstorage 21 FAQ 22 Errorindication detection 22 Cleaning 22 Conformity 22 Informationondisposal 23 Warranty 23 Se...

Page 4: ...ilable for download at www tcsag de Usedsymbolsandwarningnotices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failure to observe this warnin...

Page 5: ...communication lines e g J Y St Y with 0 8 mm diameter already existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance requirementstoprotectagainst...

Page 6: ...glass acknowledgement tone when pressing the bell button any bell bell button can be used to switch the light light symbol enclosed conversation time ex works 56 seconds can be adjusted with Service D...

Page 7: ...onnectionterminal 13 connection forService Device bellbuttonextension 5 two colouredLED 14 nameplate illumination 6 Code lock keypad 15 volume controlmicrophone 7 bipolarpluggable screw terminal 16 vo...

Page 8: ...o 0 button light switchinginbasic mode inputconfirmation in program ming mode button entryofcommandsequences andabortofincomplete com mand sequences in programming mode Technicaldata supply voltage 24...

Page 9: ...vice damage The front door station must never be sealed using silicon Condensed water must be able to escape and evaporate Openingandclosingthehousing The lower aperture is connected to the aluminium...

Page 10: ...losed in the delivery to connect lines Avoid damaging the device CAUTION Device damage The inner resistance of the door opener must not fall below 6 Ohm Strip the cable ends Connect the wires accordin...

Page 11: ...ices of the system completely Then switch on the mains voltage Install the devices of the system completely Do not connect V1 and V2 with the P a or b wire Observe the polarity when connecting the vid...

Page 12: ...is entered correctly and the contact according to the configuration of the switching input is effective Initial operation WARNING Danger to life due to electric shock Observe the safety regulations a...

Page 13: ...oil Cut the name plates to the right size Push the name plate into the gab in the name plate glass from aside ill 11 Print the name plates on the special foil You can order the foil directly at TCS Wr...

Page 14: ...dooropeneronlyduringanestablishedvoiceconnectionon off x setting the doorcallstandby time x setting the limitforthe conversation time x x setting thecalltime x setting the door release time x selectin...

Page 15: ...he mains voltage The operating LED at the power supply and control unit is on Check if no programming lock is set Before you can reprogram an already programmed bell button you have to delete the prog...

Page 16: ...programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switchedOFF 1 IftheresoundsaProgsperrtoneinstead atthefront doorstationaprogramminglockisset Youcandeact...

Page 17: ...tone soundsand a ringtonesounds atthe front doorandindoorstation 1 Release thebell button 2b alternatively Programming via floor push button if the indoorstationis inaccessible Shortlypress the floor...

Page 18: ...llbutton until the deletion tonesequence sounds Release thebellbutton 4 End programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switched OFF Programming the...

Page 19: ...timesincorrectly Afterwards the codeinputislockedfor2min Thenstartagain Ifno command isenteredwithin the next2minutes the deviceauto matically quitsthe programming mode The LEDexpires Programming 2a...

Page 20: ...ximumof8digits The programming lock cannot bedeactivatedmanually butonly withconfigoTM Determine the extended code lock function Input 12 function type Function type 0 externalcontacthas noinfluence 1...

Page 21: ...ds the code inputis lockedfor2min Thenstartagain Switchingthelightinbasicmode 1 button to confirm button toconfirmwithoutenteringacode before Aspreconditionthefunctionmusthavebeenactivated programming...

Page 22: ...xchange a andP wireorcorrect short circuit LEDexpires a wire isnotconnectedornot supplied Connectthe a wireorestablish power supply LEDexpires The buttonclamps press longer than 15sec release thebutto...

Page 23: ...point Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for qualified electricians Please conta...

Page 24: ...wister Scholl Str 7 39307Genthin Germany FON 49 0 3933 8799 10 FAX 49 0 3933 879911 www tcsag de Subjecttotechnicalchanges TCS Hotline Germany FON 494194 9881188 Fax 494194 988129 Mail hotline tcsag d...

Reviews: