25
Model SB25
Controls and Systems
Shaver Cartridge
______________________________
The shaver blade has a single edge design that
cannot be re-sharpened.
Troubleshooting
If the shaved ice becomes inconsistent in the
texture, check the blade for damage and dullness.
Replace the blade if necessary.
If there is not enough ice being shaved, check the
blade for dullness. The timing can also be adjusted
for the required ice flow.
Replacement
Step 1
Turn off the power switch and unplug the
power cord.
Step 2
Remove the ice hopper and lid. (See page 17.)
WARNING: The shaver blade is very
sharp.
Caution must be used when working in or
near the shaver assembly. Failure to follow this
instruction may result in personal injury from blade
contact.
Step 3
Remove the ice shaver cone cover by pressing the
rear tab inward and rotating the cover clockwise.
Figure 28
Step 4
Remove ice scrambler by squeezing the tabs inward
and rotating clockwise while holding the wing
securely. (
Note:
Secure the o-ring for re-assembly.)
Figure 29
Step 5
Slide the shaver cartridge out of the cone.
Figure 30
Step 6
Reassemble the system and check the ice volume
for proper calibration.