41
Models 8752 & 8756 with Horizon
®
Pump
Troubleshooting Guide
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
12. The machine will not
operate in the AUTO
mode.
a. The machine is
unplugged.
a. Plug the machine into the
wall receptacle.
-- -- --
b. The circuit breaker is off
or the fuse is blown.
b. Turn the breaker on or
replace the fuse.
-- -- --
c. Low on mix. The “MIX
OUT” light is flashing.
c. Add mix to the mix tank
and press the AUTO key.
15
d. The mix probe is not
installed properly or is
damaged.
d. Check the mix probe
installation.
29
e. The beater motor is out on
reset.
e. Reset the freezer.
15
f. The unit is off on high
head pressure.
f. Air cooled: clean the
condenser.
Water cooled: check the
water supply.
Contact a service
technician.
36
g. The power switch is in the
OFF position.
g. Place the power switch in
the ON position and press
the AUTO key.
27
Summary of Contents for Horizon 8752
Page 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Page 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Page 63: ...Model 8752P 062336 27 Rev 11 09 ...
Page 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Page 65: ...Model 8752P 062336 33 Rev 11 09 ...
Page 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Page 67: ...Model 8756P 062348 27 Rev 11 09 ...
Page 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Page 69: ...Model 8756P 062348 33 Rev 11 09 ...
Page 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...