26
Models 8752 & 8756 with Horizon
®
Pump
Operating Procedures
Step 17
Install the pressure line. Attach the quick disconnect
fitting of the pressure line to the other fitting on the mix
inlet tube, just above the flare line. Allow the other end
to hang free.
Figure 41
Step 18
Assemble the mix suction line. Attach the “weighted
end” to one opening of the suction tube.
Figure 42
Step 19
Attach the open end of the mix suction tube to the
pressure relief inlet fitting of the Horizon
®
pump.
Figure 43
Step 20
Insert the free end of the suction line and the pressure
line into the pail of sanitizing solution.
Figure 44
Repeat Steps 1 through 20
for the other side of the
freezer on the Model 8756.