![Taylor Horizon 8752 Operating Instructions Manual Download Page 32](http://html.mh-extra.com/html/taylor/horizon-8752/horizon-8752_operating-instructions-manual_822766032.webp)
28
Models 8752 & 8756 with Horizon
®
Pump
Operating Procedures
Step 6
After 5 minutes, open the prime plug. Press the PUMP
key. Pull the draw handle down and draw off the
remaining sanitizer.
Figure 49
Note:
On the Model 8756, momentarily pull down the
center draw handle to sanitize the center door spout.
Step 7
Once the sanitizer stops flowing from the door spout,
close the draw valve. Press the PUMP and WASH
keys to stop operation.
Step 8
Disconnect the pressure line from the check valve.
Drain the sanitizer. Reconnect the pressure line to the
check valve.
Repeat Steps 1 through 8
for the second freezing
cylinder on the Model 8756.
Air Flow Adjustment
Adjust air flow prior to priming the unit with mix.
Step 1
Open the prime plug.
Figure 50
Step 2
Make sure the suction line is open to air flow and is not
inserted in liquid.
Step 3
Press the PUMP key.
Step 4
Adjust the air flow to the desired setting. The flow rate
is factory set at 1.0 -- 1.4.
Figure 51
Step 5
Press the PUMP key to cancel operation.
Step 6
Prime the unit according to the operating instructions.
Make sure the air has stopped flowing from the prime
plug hole before closing the prime plug.
Summary of Contents for Horizon 8752
Page 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Page 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Page 63: ...Model 8752P 062336 27 Rev 11 09 ...
Page 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Page 65: ...Model 8752P 062336 33 Rev 11 09 ...
Page 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Page 67: ...Model 8756P 062348 27 Rev 11 09 ...
Page 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Page 69: ...Model 8756P 062348 33 Rev 11 09 ...
Page 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...