16
Models 8752 & 8756 with Horizon
®
Pump
Important: To the Operator
Power Switch
When placed in the ON position, the power switch
allows “SOFTECH” control panel operation.
Indicator Lights --
“Mix Low” and “Mix Out”
When the MIX LOW light begins to flash, it indicates
the mix tank has a low supply of mix and should be
refilled as soon as possible. When the MIX OUT light
begins to flash, it indicates the mix tank has been
almost completely exhausted and has an insufficient
supply of mix to operate the freezer. At this time, the
STANDBY and AUTO modes are locked out and the
freezer shuts down. To initiate the refrigeration
system, add mix to the tank and press the AUTO key.
The freezer will automatically begin operation.
Reset Button
The reset button is located in the decorative plate
above the “SOFTECH” controls. The reset protects
the beater motor from an overload condition. Should
an overload occur, the reset mechanism will trip.
To properly reset the freezer, press the AUTO key to
cancel the cycle. Turn the power switch to the OFF
position. Press the reset button firmly. Turn the power
switch to the ON position. Press the AUTO key to
resume normal operation. (For the Model 8756, press
the AUTO key on both sides to resume normal
operation.)
WARNING: Do not use metal objects to
press the reset button. Failure to follow this
instruction may result in serious electrical shock.
If the freezer shuts down again, contact your
authorized service technician.
“Softech” Control Operation
Mix Ref
When the MIX REF key is pressed, the light comes on,
indicating the mix cabinet refrigeration system is
operating. (For the Model 8756, there are two
touch--tone panels, one for each freezing cylinder. The
mix refrigeration system is controlled by the MIX REF
key found on the left panel. By pressing the AUTO key
on either side of the freezer, the MIX REF function is
automatically turned on.) The MIX REF function
cannot be cancelled unless the AUTO or STANDBY
mode is cancelled first.
Standby
During long “No Sale” periods it becomes necessary
to warm the product in the freezing cylinder to
approximately 35
_
to 40
_
F (1.7
_
to 4.4
_
C) to prevent
overbeating and product breakdown.
When the STANDBY key is pressed, the light comes
on, indicating the CTR (Cylinder Temperature
Retention System) has been activated. In the
STANDBY mode, the WASH, PUMP, and AUTO
functions are automatically cancelled. The MIX REF
function is automatically locked in to maintain the mix
in the cabinet.
To resume normal operation, press the STANDBY key
to cancel the cycle, and then press the AUTO key.
When the unit cycles off, the product in the freezing
cylinder will be at serving viscosity.
Wash
When the WASH key is pressed, the light comes on,
indicating beater motor operation. The STANDBY key
or AUTO modes must be cancelled first to activate the
WASH mode.
Summary of Contents for Horizon 8752
Page 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Page 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Page 63: ...Model 8752P 062336 27 Rev 11 09 ...
Page 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Page 65: ...Model 8752P 062336 33 Rev 11 09 ...
Page 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Page 67: ...Model 8756P 062348 27 Rev 11 09 ...
Page 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Page 69: ...Model 8756P 062348 33 Rev 11 09 ...
Page 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...