36
Models 8752 & 8756 with Horizon
®
Pump
Important: Operator Checklist
j
7. If your machine is air cooled, check the
condensers for accumulation of dirt and lint.
Dirty condensers will reduce the efficiency and
capacity of the machine. Condensers should be
cleaned
monthly
with a soft brush.
Note:
For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
Never use screwdrivers or other
metal probes to clean between the fins.
j
8. On water cooled units, check the water lines for
kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance
purposes.
Deteriorated
or
cracked water lines should be replaced only by
an authorized Taylor technician.
j
9. Your machine is equipped with an auxiliary
refrigeration system. Check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration
capacity of the mix cabinet. Condensers must
be cleaned
monthly
with a soft brush.
Never
use screwdrivers or other metal probes to clean
between the fins.
The Horizon
®
Pump
Figure 66
Replace the Horizon
®
pump tubing every three
months.
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser.
This is
extremely important.
Failure to follow this procedure
may cause severe and costly damage to the
refrigeration system.
Your local Taylor Distributor can perform this service
for you.
Wrap detachable parts of the freezer such as the
beater, blades, drive shaft, and freezer door. Place
these parts in a protected, dry place. Rubber trim parts
and gaskets can be protected by wrapping them with
moisture--proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.
Summary of Contents for Horizon 8752
Page 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Page 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Page 63: ...Model 8752P 062336 27 Rev 11 09 ...
Page 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Page 65: ...Model 8752P 062336 33 Rev 11 09 ...
Page 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Page 67: ...Model 8756P 062348 27 Rev 11 09 ...
Page 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Page 69: ...Model 8756P 062348 33 Rev 11 09 ...
Page 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...