83
Model C606
Operating Procedures
Step 9
Remove the discharge tube lock nut by turning it
counterclockwise. Remove the discharge lock nut
from the discharge tube. (See Figure 208.)
Figure 208
Step 10
Remove the lid by sliding it off the discharge tube.
Step 11
Remove the cylinder from the valve body. (See
Figure 209.)
Figure 209
Step 12
Remove the discharge tube from the valve body.
(See Figure 210.)
Figure 210
Step 13
Remove the 1-5/16” o-ring from the valve body, and
remove the 1” o-ring from the discharge tube.
Cleaning the Syrup Pump
Step 1
Wash and scrub all parts in an approved 100 PPM
cleaning solution (examples: Kay-5® or
Stera-Sheen®).
Step 2
Insert the black shielded brush through the tip of the
discharge tube. Move the brush back and forth to
scrub the tip of the discharge tube. (See
Figure 211.)
Figure 211