66
Model C606
Operating Procedures
150619
Sanitizing - Soft Serve Side
Step 1
Prepare a pail of an approved 100 PPM sanitizing
solution (examples: 2-1/2 gal. [9.5 liters] of Kay-5
R
or 2 gal. [7.6 liters] of Stera-Sheen
R
). USE WARM
WATER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 2
Pour the sanitizing solution over all parts in the
bottom of the mix hopper and allow it to flow into the
freezing cylinder.
Note: You have just sanitized the mix hopper
and parts; therefore, be sure your hands are
clean and sanitized before going on in these
instructions.
While the solution is flowing into the freezing
cylinder, take particular care to brush clean the mix
level sensing probes, the mix hopper, mix inlet hole,
the outside of the agitator housing, the agitator, the
air/mix pump, pump clip, mix feed tube and cotter
pin.
Step 3
Install the pump assembly at the rear of the mix
hopper. To position the pump on the drive hub, align
the drive hole in the piston with the drive crank of
the drive shaft. Secure the pump in place by slipping
the pump clip over the collar of the pump, making
sure the clip fits into the grooves in the collar.
(See Figure 155.)
Figure 155
Step 4
CAUTION!
Install the pump end of the mix feed tube and
secure with the cotter pin.
Failure to follow this
instruction could result in sanitizer spraying on the
operator.
Step 5
Prepare another pail of an approved 100 PPM
sanitizing solution (examples: Kay-5® or
Stera-Sheen®)
.
USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 6
Pour the sanitizing solution into the mix hopper.
Step 7
Brush the exposed sides of the hopper. Wait at least
5 minutes before proceeding with these instructions.
Step 8
Touch the WASH symbol
. This will cause the
sanitizing solution in the freezing cylinder to be
agitated.
Step 9
With a pail beneath the door spout, open the draw
valve and touch the PUMP symbol
. Open and
close the draw valve 6 times. Open the draw valve
and draw off the sanitizing solution.
Step 10
Touch the WASH and PUMP symbols
and
close the draw valve. (See Figure 156.)
Figure 156
IMPORTANT! The unit must NOT be placed in
AUTO until all sanitizing solution has been
removed from the freezing cylinder and proper
priming procedures have been completed.
Failure to follow this instruction may result in
damage to the freezing cylinder.
Note: Be sure your hands are clean and
sanitized before going on in these instructions.
Summary of Contents for C606
Page 6: ...Table of Contents Model C606 Notes ...
Page 16: ...10 Model C606 Operator Parts Identification 140624 Front View Figure 2 ...
Page 26: ...20 Model C606 Operator Parts Identification 140624 Accessories Figure 11 ...
Page 30: ...24 Model C606 Operator Parts Identification Beater Door Assembly Shake Side Figure 14 ...