40
Model C606
Important: To the Operator
120515
The
SERVINGS COUNTER
screen is used to check
or reset the number of servings dispensed from the
machine. (See Figure 49.)
SERVINGS COUNTER
L = 0
R = 0
Next
>
Exit
Figure 49
Reset the SERVINGS COUNTER by selecting the
AUTO symbol
to move the arrow (>) to “Next”.
The Reset Counters and Details selections will be
displayed on the next screen. (See Figure 50.)
SERVINGS COUNTER
Details
>
Reset Counters
Exit
Figure 50
Select the AUTO symbol
to move the arrow to
RESET COUNTERS. Then select the
CALIBRATION symbol
. (See Figure 51.)
SERVINGS COUNTER
Are you sure?
>
Yes
No
Figure 51
The display will ask, “Are you sure?” To reset the
counters, select the AUTO symbol
to move the
arrow to YES. Select the CALIBRATION symbol
to clear the left and right counters and return to the
SERVINGS COUNTER screen. If you do not want to
clear the serving counter, move the arrow to “No”
and select the CALIBRATION symbol
to return
to the SERVINGS COUNTER screen without
resetting the counters to zero.
Note:
The SERVINGS COUNTER will automatically
reset to zero when the machine is brush cleaned.
(See Figure 52.)
SERVINGS COUNTER
L = 0
R = 0
Next
>
Exit
Figure 52
Access the Details screen by selecting “Next” in the
SERVINGS COUNTER screen. Move the arrow to
“Details” and then select the CALIBRATION symbol
. (See Figure 53.)
SERVINGS COUNTER
>
Details
Reset Counters
Exit
Figure 53
The counter menu will also display details for the
number of servings for each flavor (chocolate,
strawberry, vanilla, option, unflavored, and soft
serve), and count the method that ended the draw
for each flavor (pyroelectric sensor detection,
manually selecting a flavor key, draw safety timeout,
and other). (See Figure 54.)
Example:
CHOCOLATE
Pyro = 0
Oper = 0
Time = 0 Other = 0
>
Next
Figure 54
Pyro
= Pyrosensor detected and triggered the end
of the draw.
Time
= The Draw Safety Time setting was reached
before the pyrosensor detection or before a flavor
key was selected.
Oper
= A flavor key was selected to terminate the
draw.
Other
= Any draw termination that is not Pyro, Time,
or Oper (example: power switch turned off while
product is dispensing)
Summary of Contents for C606
Page 6: ...Table of Contents Model C606 Notes ...
Page 16: ...10 Model C606 Operator Parts Identification 140624 Front View Figure 2 ...
Page 26: ...20 Model C606 Operator Parts Identification 140624 Accessories Figure 11 ...
Page 30: ...24 Model C606 Operator Parts Identification Beater Door Assembly Shake Side Figure 14 ...