67
Model C602
Troubleshooting
Shake Dispensing Mechanism Troubleshooting
PROBLEM
CAUSE
REMEDY
1. Draw valve will not open.
a. Power switch is off.
a. Place the power switch in the ON
position.
b. The solenoid bumper screw is
disengaged.
b. Align the actuator plate and secure
the bumper screw to the solenoid
plunger.
c. The draw valve is binding in the
freezer door.
c. Replace defective component.
d. The draw solenoid is adjusted too
high.
d. Adjust the draw solenoid to the
proper height. (See page 55.)
e. The solenoid fuse has blown.
e. Inspect/replace the 15A fuse
located in the front control channel.
f. Loose wire connection.
f. Check the circuit for power
interruption and repair it.
g. Defective rectifier board.
g. Replace the rectifier board.
h. Defective pull or hold relay.
h. Replace defective relay.
i.
Defective solenoid.
i.
Replace the solenoid.
j.
Defective interface board.
j.
Replace the interface board.
k. Defective touch key on the dec
plate.
k. Replace the dec plate.
2. Occasionally the draw valve does
not open.
a. The dispensing mechanism is out
of alignment.
a. Realign the dispensing
mechanism. (See page 54.)
b. Improper lubrication of the draw
valve.
b. Lubricate according to instructions
in the Operator’s Manual.
c. Incorrect o-rings installed on the
draw valve.
c. Install correct o-rings - part no.
020571-1 (F treated).
d. The draw valve is binding in the
freezer door.
d. Replace defective component.
3. Draw valve opens momentarily.
a. The draw valve solenoid is
adjusted too high.
a. Adjust the draw solenoid to the
proper height. (See page 55.)
b. The portion control system is
terminating the draw after two
seconds.
b. See Portion Control
Troubleshooting on page 69
.
c. The draw safety time is set too
low.
c. Adjust the draw safety time in the
Service Menu.
d. Defective hold relay.
d. Replace the relay.
e. Loose wire connection in the draw
solenoid circuit.
e. Check the circuit for power
interruption and repair it.
Summary of Contents for C602
Page 1: ...Model C602 Combination Shake Soft Serve Freezer Service Manual 057888 S 4 6 04...
Page 12: ...9 Model C602 Systems Controls and Operations Refrigeration System Schematic Figure 2...
Page 42: ...39 Model C602 Systems Controls and Operations Glycol Path Rear View Figure 83...
Page 46: ...43 Model C602 Systems Controls and Operations Control Overview Figure 86...
Page 75: ...72 Troubleshooting Model C602 Notes...
Page 78: ...75 Model C602 Parts Notes...
Page 79: ...76 Parts Model C602 Main Exploded View Figure 102...
Page 87: ...84 Parts Model C602 Control Assembly X55966 33 Figure 108...
Page 90: ...87 Model C602 Parts Torque Coupling Assembly X54722...
Page 113: ...Model C602 059480 33 Rev 4 04...
Page 114: ...Model C602 059480 58 Rev 4 04...