62
Troubleshooting
Model C602
General Troubleshooting
(Cont’d.)
PROBLEM
CAUSE
REMEDY
28. “Compressor on too long” fault
message.
a. Inadequate pump operation.
a. Check pump operation. Assemble
pump according to instructions in
the operator’s manual.
b. Draw rate set too fast.
b. Set the draw rate at 5 - 7-1/2 oz.
(142 213 g) of product per 10
seconds.
c. Inadequate air flow.
c. Provide 3” (76 mm) air space
around sides.
d. Faulty blower baffle.
d. Repair or replace blower baffle.
e. Inadequate AXV settings.
e. Set AXV at proper setting. (See
“Running Specifications”.)
29. Symbol selection is delayed.
a. Defective dec plate.
a. Replace dec plate.
Summary of Contents for C602
Page 1: ...Model C602 Combination Shake Soft Serve Freezer Service Manual 057888 S 4 6 04...
Page 12: ...9 Model C602 Systems Controls and Operations Refrigeration System Schematic Figure 2...
Page 42: ...39 Model C602 Systems Controls and Operations Glycol Path Rear View Figure 83...
Page 46: ...43 Model C602 Systems Controls and Operations Control Overview Figure 86...
Page 75: ...72 Troubleshooting Model C602 Notes...
Page 78: ...75 Model C602 Parts Notes...
Page 79: ...76 Parts Model C602 Main Exploded View Figure 102...
Page 87: ...84 Parts Model C602 Control Assembly X55966 33 Figure 108...
Page 90: ...87 Model C602 Parts Torque Coupling Assembly X54722...
Page 113: ...Model C602 059480 33 Rev 4 04...
Page 114: ...Model C602 059480 58 Rev 4 04...