Systems, Controls and Operations
Model C602
CAL SYRUP TIME
This option allows the service technician to adjust
the Calibrate Syrup Time which determines the flow
rate of the syrup.
Example: 1 oz.(28 g) syrup dispensed in 5 seconds.
The recommended Cal Syrup Time for standard
shakes is 5.0 seconds and is 7.0 seconds for Triple
Thick Shakes.
The following screen is displayed by selecting this
option: (See Figure 69.)
CAL SYRUP TIME
TIME : 5.0 SEC
Figure 69
Select the AUTO symbol
to increase the time
setting or the OPTIONAL FLAVOR symbol
to
decrease the setting. Select the CALIBRATION
symbol
to save the setting and return to the
Service Menu.
DRAW SAFETY TIME
This option allows the service technician to adjust
the Draw Safety Time used for closing the shake
draw valve in the AUTO Mode if the fill level is not
detected by the portion control sensor. The Draw
Safety Time should be set approximately 5 seconds
longer than the amount of time it takes to fill the
largest serving size.
The following screen is displayed by selecting this
option. (See Figure 70.)
DRAW SAFETY TIME
TIME : 11 SEC
Figure 70
Press the AUTO symbol
to increase the Draw
Safety Time setting or the OPTIONAL FLAVOR
symbol
to decrease the setting. Select the
CALIBRATION symbol
to save the setting and
return to the Service Menu.
EDIT UNIT ID
This option allows the service technician to enter the
factory Bill of Material (B.O.M.) code used to
assemble the machine, the freezer Serial Number
and the Store Identification Number. This
information must be programmed in the service
menu in order to view the information in the
SYSTEM INFORMATION screens. (See Figures 71,
72 & 73.)
ENTER FREEZER BOM
C 6 0 2 3 3 H 0 0 0
_
Figure 71
Select the AUTO symbol
to increase the value or
OPTIONAL FLAVOR symbol
to decrease the
value. Select the CALIBRATION symbol
to move
the cursor to the right and advance to the serial
number screen.
ENTER FREEZER SN
K 0 0 0 0 0 0 0
_
Figure 72
Enter the serial number from the unit’s data label in
the same manner as the BOM, then select the
CALIBRATION symbol
to save the setting and
advance to the store identification screen.
ENTER STORE ID
0 0 0 0 0
_
Figure 73
Enter the store number, then select the
CALIBRATION symbol
to save the setting and
return to the Service Menu.
Summary of Contents for C602
Page 1: ...Model C602 Combination Shake Soft Serve Freezer Service Manual 057888 S 4 6 04...
Page 12: ...9 Model C602 Systems Controls and Operations Refrigeration System Schematic Figure 2...
Page 42: ...39 Model C602 Systems Controls and Operations Glycol Path Rear View Figure 83...
Page 46: ...43 Model C602 Systems Controls and Operations Control Overview Figure 86...
Page 75: ...72 Troubleshooting Model C602 Notes...
Page 78: ...75 Model C602 Parts Notes...
Page 79: ...76 Parts Model C602 Main Exploded View Figure 102...
Page 87: ...84 Parts Model C602 Control Assembly X55966 33 Figure 108...
Page 90: ...87 Model C602 Parts Torque Coupling Assembly X54722...
Page 113: ...Model C602 059480 33 Rev 4 04...
Page 114: ...Model C602 059480 58 Rev 4 04...